C-8
Ver. 1
C. ADJUSTMENT METHOD
C-7070 Wide Zoom
Preparation:
POWER switch: ON
Subject: Rotation within ± 10 degrees
Luminance: BV2-6
Temperature: 25 degrees ± 5
Adjusting method:
1. Set the parallax adjustment chart at 1241.94 mm ± 10
mm from CCD.
2. Double-click on the DscCalDi.exe.
3. Click the "PAF Cal". "PAF Calibration Dialog" is opened.
4. Click the "ON" in the PAF Disp. Sensor data graph will be
displayed.
5. Align the AF frame, shown near the center of the LCD
display, with the lateral adjustment chart and set the
camera. (See above figure.)
6. Click the "Parallax".
7. Parallax adjustment value will appear on the screen.
8. Click the OK.
Camera
1241.94 mm
±
10 mm
Parallax
adjustment chart
Chart for parallax adjustment
AF frame
6-2. Parallax Adjustment
Adjustment value determination is effectuated using
"PAF_RIGHT_LEFT" value.
LEFT=L1, L2, L3, RIGHT=R1, R2, R3 and the ideal values
and acceptable values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
Ideal value of LEFT optic axis difference (L3) = Ð8
Acceptable value of LEFT optic axis difference (L3)
= ideal value ± 10 = Ð18~2
Ideal value of RIGHT optic axis difference (R3) = 14
Acceptable value of RIGHT optic axis difference (R3)
= ideal value ± 10 = 4~24
6-3. Distance Adjustment
Preparation:
POWER switch: ON
Subject: Rotation within ± 10 degrees
Luminance: BV2-6
Temperature: 25 degrees ± 5
Note:
Should adjustment be interrupted before completion, the unit
will start over from the first temperature reading obtained.
Adjusting method:
1. Set the camera turn to the chart.
2. Double-click on the DscCalDi.exe.
3. Click the "PAF Cal". "PAF Calibration Dialog" is opened.
4. Click the "Temp 1". The temperature reading obtained
prior to the distance adjustment is indicated.
5. Enter "0" on the left of "Calibration".
6. Click "Calibration" to initialize.
7. After initializing, adjustment value will be cleared and dis-
played.
8. Set the chart for 0.5 m distance adjustment at 0.5 m from
PAF.
9. Enter "50" on the left of "Calibration".
10. Click "Calibration".
11. Distance adjustment value will appear on the screen.
Camera
2.4 m
±
10 mm
0.5 m
±
10 mm
Distance
adjustment chart
Содержание CAMEDIA C-7070 Wide Zoom
Страница 1: ...Global Support Service Department OLYMPUS IMAGING CORP Ver 1 INDEX REPAIR MANUAL C 7070 Wide Zoom...
Страница 26: ...C 13 Ver 1 C ADJUSTMENT METHOD C 7070 Wide Zoom...
Страница 30: ...E 1 Ver 1 C 7070 Wide Zoom E NOTICE OF MODIFICATION...
Страница 31: ...F 1 Ver 1 C 7070 Wide Zoom F APPLICATION LIST OF GREASE AND CHEMICALS...
Страница 32: ...G 1 Ver 1 C 7070 Wide Zoom G SPECIAL JIGS AND TOOLS...