C-7
Ver. 1
C. ADJUSTMENT METHOD
C-7070 Wide Zoom
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
2
)
Adjusting method:
1. Set the camera 0 cm from the pattern box. (Do not enter
any light.)
2. Double-click on the DscCalDi.exe.
3. Select "CCD Black" on the LCD "Test", and click the "Yes".
4. After the adjustment is completed, the number of defect
will appear.
(When adjustment is failed, "detect_ng BLACK x, y" will
display.)
5. Click the OK.
Camera
Pattern box
(color viewer)
5. CCD Black Point And White Point Defect Detect
Adjustment In Lighted
6. PAF Adjustment
6-1. Uniform Adjustment
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
2
)
Note:
Orient the PAF sensor towards the viewer.
Adjusting method:
1. Set the camera 0 cm from the pattern box.
2. Double-click on the DscCalDi.exe.
3. Click the "PAF Cal". "PAF Calibration Dialog" is opened.
4. Click the "Uniformity".
5. Uniformity adjustment value will appear on the screen.
6. Click the OK.
7. This adjustment is to check whether there is a pixel defi-
ciency in the sensor by viewing the graph that appears on
the camera’s LCD. A pixel deficiency or other trouble will
result in fluctuations appearing on the graph.
Camera
Pattern box
(color viewer)
Содержание CAMEDIA C-7070 Wide Zoom
Страница 1: ...Global Support Service Department OLYMPUS IMAGING CORP Ver 1 INDEX REPAIR MANUAL C 7070 Wide Zoom...
Страница 26: ...C 13 Ver 1 C ADJUSTMENT METHOD C 7070 Wide Zoom...
Страница 30: ...E 1 Ver 1 C 7070 Wide Zoom E NOTICE OF MODIFICATION...
Страница 31: ...F 1 Ver 1 C 7070 Wide Zoom F APPLICATION LIST OF GREASE AND CHEMICALS...
Страница 32: ...G 1 Ver 1 C 7070 Wide Zoom G SPECIAL JIGS AND TOOLS...