Olympus BX3-SSU Скачать руководство пользователя страница 1

INSTRUCTIONS

BX3-SSU

SCANNING STAGE WITH ULTRASONIC

This instruction manual is for the Olympus Scanning Stage with Ultrasonic Model BX3-SSU.
To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use 
of the scanning stage with ultrasonic, we recommend that you study this manual thoroughly 
before operating the microscope. In addition, be also sure to read the instruction manual for the 
microscope on which the scanning stage with ultrasonic is installed.
Retain this instruction manual in an easily accessible place near the work desk for future reference. 

A X 8 2 1 3

[TYPE-2]

Optical Microscope Accessory

Downloaded from 

ManualsNet.com

 search engine

Содержание BX3-SSU

Страница 1: ...scanning stage with ultrasonic we recommend that you study this manual thoroughly before operating the microscope In addition be also sure to read the instruction manual for the microscope on which t...

Страница 2: ...io frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this product in a residential area is li...

Страница 3: ...ving the Stage 1 Center Plate with 50mm Hole IX CP50 3 Replacing the Fuses 2 Stage Clips IX SCL 5 OPTIONAL ACCESSORIES 9 n PROPER SELECTION OF THE POWER SUPPLY CORD 17 18 6 SPECIFICATIONS 7 TROUBLESHO...

Страница 4: ...Always use the power cord provided by Olympus If no power cord is provided please select the proper power cord by referring to the section PROPER SELECTION OF THE POWER SUPPLY CORD at the end of this...

Страница 5: ...he power cord for safety 8 Do not touch the actuator of the stage barehanded or do not attach foreign objects such as oil grease etc on it Otherwise the stage could break down 9 The operating sound of...

Страница 6: ...ltrasonic The modules marked are not part of the scanning stage with ultrasonic product Scanning stage with ultrasonic BX3 SSU Control box BX3 CBH IX3 CBH Microscope frame BX63F IX83P1ZF IX83P2ZF IX73...

Страница 7: ...Center plate with 50 mm hole IX CP50 Supersonic stage control box Provided with BX3 SSU Pilot lamp Main switch I ON OFF RS232C connector DRIVE connector SENSOR connector MCXY connector TRIG OUT connec...

Страница 8: ...ob Coarse fine selector button Pushed in Coarse adjustment Out position Fine adjustment The factory settings of the stage displacement per turn are 10 mm for the coarse adjustment and 0 2 mm for the f...

Страница 9: ...t does not cause any problem for the product performance The stage may be vibrated slightly in some cases when starting the stage but the product is not damaged The stage or the slide holder may be in...

Страница 10: ...g display 4 Tap the Setting 2 tab 3 and then tap the Auto Compensation button 4 5 When the auto compensation confirmation display appears tap OK to start auto compensation The stage moves automaticall...

Страница 11: ...nsation In this case turn the power of BX3 SSU Control Box to OFF and perform the Auto Compensation again after moving the stage from front to back and from side to side several times with a hand CAUT...

Страница 12: ...t may be deformed CAUTION CAUTION 2 Stage Clips IX SCL Fig 10 The stage clips are used to fix a dish or petri dish sample 1 Screw the stage clips 2 into the two stage clip holes on the scanning stage...

Страница 13: ...oaxial knobs with coarse fine selector button Displacement per turn Coarse adjustment 10 mm Fine adjustment 0 2 mm Dimensions weight 223 W x 88 H x 54 D mm approx 1 kg Control box Rating 100 120 220 2...

Страница 14: ...Setting of the touch panel controller d The stage movement has become unsmooth after a long period of use Fine particles produced due to wear of the stage s sliding surfaces are deposited Set the con...

Страница 15: ...owing diagram shows only the cable connections associated with the scanning stage with ultrasonic When connecting each connector align the connector orientation correctly and insert the connector all...

Страница 16: ...nd 3 with the clamping screw attached with BX63 from the lower side of the stage fixing pillar of BX63 Use Allen wrench 40x70mm attached with BX63 for tightening Clamping screw attached with BX3 SSU T...

Страница 17: ...5 6 7 Fig 13 Fig 14 Fig 15 Fig 16 2 Place the shim rings 3 provided with BX3 SSU over the screw holes 2 on the rear side of the microscope 3 Place the stage on the microscope so that the screw holes...

Страница 18: ...m the edge on the stage side with the cable binder 8 provided with BX3 SSU 6 Attach the cable holder 9 provided with BX3 SSU on the microscope See Fig 18 for the position to the attach 7 Pass the cabl...

Страница 19: ...OF THE POWER SUPPLY CORD at the end of this instruction manual 1 Insert the connector 1 of the power cord firmly into the connector 2 The power cord should be connected to a grounded earthed 3 conduct...

Страница 20: ...d A power supply cord should be certified by one of the agencies listed in Table 1 or comprised of cordage marked with an agency marking per Table 1 or marked per Table 2 The fittings are to be marked...

Страница 21: ...HAR 10 10 30 N V KEMA KEMA KEUR HAR 10 30 30 SEMKO AB Svenska Elektriska Materielkontrollanstalter SEMKO HAR 10 10 50 sterreichischer Verband f r Elektrotechnik VE VE HAR 30 10 50 Danmarks Elektriske...

Страница 22: ...MEMO Downloaded from ManualsNet com search engine...

Страница 23: ...Downloaded from ManualsNet com search engine...

Страница 24: ...oul 06153 Korea Distributed by Manufactured by 48 Woerd Avenue Waltham MA 02453 U S A Shinjuku Monolith 2 3 1 Nishi Shinjuku Shinjuku ku Tokyo 163 0914 Japan www olympus global com Printed in Japan 20...

Отзывы: