background image

Page

 

8 from

 

13

940851000

_09_001

The differential value can be set between 

 

0.2 °

C and

 4.0 °

C.

The factory default value is 

  0.

2

 °

C.

G

.

 

  

          (Heat/Cold)

.

 HEATING MODE

.

            The device can control only heating 

units (e.g. diesel burners).

H.          (Time) HOUR METER.

In this screen position you can see the total 
operation  hours  of  the  burner.  This  value 
can not be altered by the keypad but can be 
reset  if  the  battery  is  removed.  The 
maximum value is 9.999 hours.

I

.   

 

       (

Factory settings)   SELECTING 

THE FACTORY DEFAULT SETTINGS

.

If for any reason there is the need to restore 
the thermostat to its factory default settings 
then  this  setting  will  restore  then  if  you 
select                 and press the key               

.

This 

does not affect the time and date settings

.

The factory default setting is 

       .

11. 

CHANGING THE BATTERY

When  the  screen  shows  the          symbol             
the  unit  warns  the  user  that  the  batteries 
have limited energy and that they must be 
replaced in the next 3 weeks. To replace the 
batteries simple remove the cover (Fig. 2) 
to  expose  the  battery  compartment. 
Remove  the  batteries  and  within  30 
seconds reinsert new ones in order to avoid 
a reset of the device. Should this happen it 
will  require  to  adjust  the  time  and  date 
again. All other setting remain unaffected.   
Avoid  replacing  the  batteries  with  the 
backlight  activated,  this  will  immediately 
reset the device and the hour meter. Take 
care of the battery orientation and insert the 
new  batteries  according  to  the  graphic 
representation etched on the plastic base. 
The  reverse  installation  will  not  harm  the 
device but it will not permit it to operate.
The battery life time has been design to be 
approximately  one  year.  Factors  that 
influence the battery life are prolong use of 
the  keyboard  with  the  backlight  active, 
increased temperature and humidity as well 
as battery quality

12. ANTI-ICE PROTECTION

If  the  room  temperature  in  which  the 
thermostat is installed falls below 

 5°

C, the 

unit activates the burner output irrelevant of 
the  ON  or  OFF  state  of  the  thermostat

 

to 

prevent ice build up. The burner output is 
active  for  as  long  as  the  temperature  is 
below 

C

.

1

3

CLEANING THE THERMOSTAT

To  clean  the  device  use  a  damp  cloth  to 
remove any dust or stains from the covers. 
Do not use any liquid or dissolvers that will 
damage the plastic covers.

1

4

SCREEN MESSAGES

Following  you  can  see  a  complete  list  of 
screen  messages  that  can  be  seen  by 
consecutively pressing the          key:
        = 

 =Time and date setting

.

Set Time

 

 = Daily program selection

.

       Day

  

   = 

 = Weekly program selection.

    

Week

         = 

 = Operation mode selection

.

  Mode

         = 

 = Temperature unit

.

  

Unit

      = 

 = Screen illumination

.

Backlight

  

 = Burner output indication LED.

        LED

                   = 

 = Manual temperature 

Time out

time

.

         = 

 = Upper limit 

High Temperature Limit

for manual temperature adjustment.

         = 

 = Lower limit 

Low Temperature Limit

for manual temperature adjustment.

         = 

 = Active boiler time

Boiler Time

         = 

 = Differential for burner 

Differential

relay

.

          = 

 = Absence program.

Absent

          = 

 = Night program.

Night

   

 = Heat operation mode.

        Heat

          = RF = Wirelless connection setting

         = 

 = Factory default settings.

  

Factory

MISCELLANEOUS INDICATIONS

       = 

 = keyboard lock.

Lock

         = 

 = unlock keyboard.

 

  Unlock

       = 

 = Save settings to memory.

    Save

        = 

 = Manual program

    User

       

  =  Celsius 

   

Degree  Celsius

temperature unit.

       

  =  Fahrenheit 

     

Degree  Fahrenheit

temperature unit.

         = 

= Program number 

Program 1 to 10 

from 1 to 10.

MENU

ENTER

Содержание BS-850/R

Страница 1: ...S 851 T BS 850 R BS 851 R Only for BS 851 R CONTROL AND INDICATIOR DESCRIPTION Thermostat activation Thermostat deactivation Increase value Decrease value Presence indicator Thermostat active Thermostat inactive Battery state indicator Ascending or descending temperature indicator When the selection is less than the actual temperature When the selection the differential is more than the actual tem...

Страница 2: ...or selection Select normal or night program Go to the previous item or selection Select and confirm installation settings Daily program activation indicator Weekly program activation indicator Manual program activation indicator Day of the week indicator Night program activation indicator Burner activation indicator Boiler activation indicator valid only for the BS 851 R Normal program activation ...

Страница 3: ... serial number located inside the receiver or scan the QR Code on the included card Otherwise you can insert the serial number by typing the 32digit on the included card Figure 2 Figure 3 2 Figure 4 CONTENTS CONTENTS Setting up the device page 3 Entering the MENU page 5 Day or Night operation page 5 Boiler activation selection page 5 Presence selection page 5 Keypad lock page 6 Setting time date p...

Страница 4: ...n Figure 1 on the thermostat and at the end the SEND icon from the application Figure 7 When they connect the LD4 must blink every 2 seconds while the LD5 must be off which means there is internet connection By finishing the process successfully you will be able to guide to the main screen of the app and your device will be visible furthermore you can control it The screen of the thermostat is ref...

Страница 5: ...f the program that was running before absence mode was selected GENERAL When the plastic battery separator is removed the unit is automatically activated and shows all the screen indicators for 1 then the firmware version is shown and finally the screen enters final operation status In the center of the screen you can see the current temperature The clock has the hour 00 00 the date is 1 January F...

Страница 6: ... consecutive presses of the key you can select the remaining programs of the 24 hour cycle 10 in total and can set the required time periods and temperatures as described above Please note that for every program define only the start time since the end time is the start time of the next program For example if you desire a temperature of 23 0º C from 14 00 to18 00 in program 1 set the start time 14...

Страница 7: ...the top right of the screen The factory default is Β Unit TEMPERATURE UNIT The option are or Degree Celsius ή Degree Fahrenheit and regard the display of the temperature in ºC or ºF Depending on the selection the symbol ºC or ºF are shown on the center right of the screen C B a c k L i g h t S C R E E N ILLUMINATION With this setting you can turn off the screen illumination in order to conserve ba...

Страница 8: ...ut it will not permit it to operate The battery life time has been design to be approximately one year Factors that influence the battery life are prolong use of the keyboard with the backlight active increased temperature and humidity as well as battery quality 12 ANTI ICE PROTECTION If the room temperature in which the thermostat is installed falls below 5 C the unit activates the burner output ...

Страница 9: ... screen shows with the Mode blinking 4 Press the key and the starts to blink With the keys and select the operation mode Day daily program 5 Press the key to return to the previous screen with the blinking 6 Press the key 8 times and the screen shows with the blinking Now you are in the daily programming sub menu that has a 10 program capability 7 Press the key and the screen shows with the blinki...

Страница 10: ...is blinking The screen will show the message briefly and the settings will be stored in to the devices memory 6 Activate the device using the key The weekly program will start to execute as defined In order for the program to execute correctly make sure you have programmed the device clock with the correct time WIRELESS CONNECTION SETTING After installing the peripheral received BS 851 R press the...

Страница 11: ...een will blink The interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs according to the state before the interruption until the communication is automatically restored with the thermostat maximum delay of 6 minutes so the outputs will change according to the new commands...

Страница 12: ... is ready to operate Fig 4 To install the BS 851 R remove the front cover with a screwdriver Fig 4 Mark and drill the mounting holes according to the schematic in page 11 Mount the device using the supplied mounting accessories Holes Aand B as shown in Fig 5 Do the electrical connections according to Fig 5 Connect the phase to the L terminal and the neutral to the N terminal this is used to power ...

Страница 13: ...o repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr TECHNICAL CHARACTERISTICS POWERED BY 2 Alkaline ΑΑ BS ...

Отзывы: