background image

1. 

SMARTPHONE CONNECTION

1

)  Download  for  free  our  application  from 

Google  Play  by  scanning  with  your 
smartphone the QR code (Figure 2) or 
make  a  search  typing  “Olympia

 

electronics thermostat”.

2

)

 

In the start up screen press

 

No

 

account

 

yet

Create  one

 

(Figure  3)

.

 

After 

finishing  the  process  successfully  you 
will  have  to  confirm  the  e-mail  address 
that you registered. With these data you 
can log in.

3) 

If you want to add a device to your home 

network firstly you have to connect your 
smartphone  to  the  network  which  your 
thermostat will be connected.

4) 

To add the thermostat to the application: 
In the application touch the 

'+'

 icon to the 

bottom left corner of the screen (Figure 
4). By selecting scan the QR Code with 
the  camera

 

scan  the  serial  number 

located  inside  the  receiver  or  scan  the 
QR  Code  on  the  included  card. 
Otherwise  you  can  insert  the  serial 
number  by  typing  the  32digit  on  the 
included card.

Figure 2

Figure 3

2

Figure 4

CONTENTS

CONTENTS

Setting up the device, page 

3

Entering the MENU, page

 5

Day or Night operation

page

 5

Boiler activation selection, page

 5

Presence selection

page

 5 

Keypad lock

page

 6

Setting time

-

date

page

 6

Setting the daily program

page

 6

Setting the weekly program

page

 

6

Setting the limits of the manual program

page

 7

Thermostat operation mode

page

 7

Temperature indication unit

page

 

7

Screen illumination

page 7

Burner output indicator, page 7
Manual operation time, page

 

7

Differential value, page

 

7

Hour meter, page

 8

Factory settings, page

 8

Battery changing, page

 8

Screen messages, page 8
Daily programming example, page

 

9

Weekly programming example, page

 1

0

Communication errors, page

 1

1

Page

 

3 from

 

13

940851000

_09_001

Содержание BS-850/R

Страница 1: ...S 851 T BS 850 R BS 851 R Only for BS 851 R CONTROL AND INDICATIOR DESCRIPTION Thermostat activation Thermostat deactivation Increase value Decrease value Presence indicator Thermostat active Thermostat inactive Battery state indicator Ascending or descending temperature indicator When the selection is less than the actual temperature When the selection the differential is more than the actual tem...

Страница 2: ...or selection Select normal or night program Go to the previous item or selection Select and confirm installation settings Daily program activation indicator Weekly program activation indicator Manual program activation indicator Day of the week indicator Night program activation indicator Burner activation indicator Boiler activation indicator valid only for the BS 851 R Normal program activation ...

Страница 3: ... serial number located inside the receiver or scan the QR Code on the included card Otherwise you can insert the serial number by typing the 32digit on the included card Figure 2 Figure 3 2 Figure 4 CONTENTS CONTENTS Setting up the device page 3 Entering the MENU page 5 Day or Night operation page 5 Boiler activation selection page 5 Presence selection page 5 Keypad lock page 6 Setting time date p...

Страница 4: ...n Figure 1 on the thermostat and at the end the SEND icon from the application Figure 7 When they connect the LD4 must blink every 2 seconds while the LD5 must be off which means there is internet connection By finishing the process successfully you will be able to guide to the main screen of the app and your device will be visible furthermore you can control it The screen of the thermostat is ref...

Страница 5: ...f the program that was running before absence mode was selected GENERAL When the plastic battery separator is removed the unit is automatically activated and shows all the screen indicators for 1 then the firmware version is shown and finally the screen enters final operation status In the center of the screen you can see the current temperature The clock has the hour 00 00 the date is 1 January F...

Страница 6: ... consecutive presses of the key you can select the remaining programs of the 24 hour cycle 10 in total and can set the required time periods and temperatures as described above Please note that for every program define only the start time since the end time is the start time of the next program For example if you desire a temperature of 23 0º C from 14 00 to18 00 in program 1 set the start time 14...

Страница 7: ...the top right of the screen The factory default is Β Unit TEMPERATURE UNIT The option are or Degree Celsius ή Degree Fahrenheit and regard the display of the temperature in ºC or ºF Depending on the selection the symbol ºC or ºF are shown on the center right of the screen C B a c k L i g h t S C R E E N ILLUMINATION With this setting you can turn off the screen illumination in order to conserve ba...

Страница 8: ...ut it will not permit it to operate The battery life time has been design to be approximately one year Factors that influence the battery life are prolong use of the keyboard with the backlight active increased temperature and humidity as well as battery quality 12 ANTI ICE PROTECTION If the room temperature in which the thermostat is installed falls below 5 C the unit activates the burner output ...

Страница 9: ... screen shows with the Mode blinking 4 Press the key and the starts to blink With the keys and select the operation mode Day daily program 5 Press the key to return to the previous screen with the blinking 6 Press the key 8 times and the screen shows with the blinking Now you are in the daily programming sub menu that has a 10 program capability 7 Press the key and the screen shows with the blinki...

Страница 10: ...is blinking The screen will show the message briefly and the settings will be stored in to the devices memory 6 Activate the device using the key The weekly program will start to execute as defined In order for the program to execute correctly make sure you have programmed the device clock with the correct time WIRELESS CONNECTION SETTING After installing the peripheral received BS 851 R press the...

Страница 11: ...een will blink The interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs according to the state before the interruption until the communication is automatically restored with the thermostat maximum delay of 6 minutes so the outputs will change according to the new commands...

Страница 12: ... is ready to operate Fig 4 To install the BS 851 R remove the front cover with a screwdriver Fig 4 Mark and drill the mounting holes according to the schematic in page 11 Mount the device using the supplied mounting accessories Holes Aand B as shown in Fig 5 Do the electrical connections according to Fig 5 Connect the phase to the L terminal and the neutral to the N terminal this is used to power ...

Страница 13: ...o repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr TECHNICAL CHARACTERISTICS POWERED BY 2 Alkaline ΑΑ BS ...

Отзывы: