Point A

 

mounting point

for wall mounting

Point A,

 

mounting point

for wall mounting

Point 

Β

Angle or

corner

mounitng

Point C

Cable entry

Point C

Cable entry

Page 3 of 5

Photo 4

Wireless motion detect

or

 

includes 

-s

 

its settings 

2 DIP witches for 

(

D

S

1

).

DIP

-

switch 1:

 

ON

 ensures input and output delays for detectors installed at the entrance 

of

 a building. 

OFF

 allows the

                       

detector to trigger an alarm immediately if the control panel is armed. Th

e DIP-switch

 has an effect only if

                       

the detector is programmed in physical response from the control panel (zone

 with delay

 or zone without

                       

delay).

Attention!!

 Selecting the delay zone from the board is required by BS-468 / A.

DIP

-

switch 2:

 

W

hen 

is 

set to 

OFF

, the device is in normal mode

. W

hen 

is 

set to

 

ON

 it is in high sensitivity mode and

                        

increases the detection range.

It also has a terminal for connecting an external magnetic contact which, when not in use, must be short-circuited.

Wall mounting

Angle mounting

Corner mounting

INTERNAL LAYOUT AND SETTINGS (continued)

INTERNAL LAYOUT AND SETTINGS (continued)

DIP-SWITCH SETTINGS

DIP-SWITCH SETTINGS

Photo 3

DS1

Connection

Terminal

Settings
Dip-switch

Tamper
Switch

Battery
CR123A

Input stage
shielding

Infrared
sensor

Circuit board

retaining screw

9214

70000

_09_005

Содержание BS-470

Страница 1: ...ither on a flat surface or at an angle of surfaces when required The device must be mounted in such a position in order to permit the best possible surveillance The mounting height should be between 2 2 and 2 5 meters with an ideal height of 2 4 metres In order to avoid unintended false alarms the detectors must not be mounted in areas that have hot air or air drafts in general such as over radiat...

Страница 2: ...ted to gently remove the circuit board by removing its retaining screw as shown in the photo 3 of page 3 Take care not to touch the IR sensor surface This will affect is operation Photograph 4 page 3 shows the interior of the plastic base as well as the cable entry and mounting hole positions To mount the unit to the wall increase the hole diameter of points Α to 4 mm using a suitable drill bit an...

Страница 3: ...from the control panel zone with delay or zone without delay Attention Selecting the delay zone from the board is required by BS 468 A DIP switch 2 When is set to OFF the device is in normal mode When is set to ON it is in high sensitivity mode and increases the detection range It also has a terminal for connecting an external magnetic contact which when not in use must be short circuited Wall mou...

Страница 4: ... the worst possible conditions eg closed doors Finally in case of home improvements or renovation it is suggested to perform a range test again RANGE TEST RANGE TEST BATERRY REPLACEMENT BATERRY REPLACEMENT The detector checks its battery voltage and transmits the information to the panel When the control panel displays a low battery indicator the detector will continue to operate for at least 2 we...

Страница 5: ...ight to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr POWER SUPPLY BATTERY LIFE COMMUNICATION RANGE DE...