Point A
mounting point
for wall mounting
Point A,
mounting point
for wall mounting
Point
Β
Angle or
corner
mounitng
Point C
Cable entry
Point C
Cable entry
Page 3 of 5
Photo 4
Wireless motion detect
or
includes
-s
its settings
2 DIP witches for
(
D
S
1
).
DIP
-
switch 1:
ON
ensures input and output delays for detectors installed at the entrance
of
a building.
OFF
allows the
detector to trigger an alarm immediately if the control panel is armed. Th
e DIP-switch
has an effect only if
the detector is programmed in physical response from the control panel (zone
with delay
or zone without
delay).
Attention!!
Selecting the delay zone from the board is required by BS-468 / A.
DIP
-
switch 2:
W
hen
is
set to
OFF
, the device is in normal mode
. W
hen
is
set to
ON
it is in high sensitivity mode and
increases the detection range.
It also has a terminal for connecting an external magnetic contact which, when not in use, must be short-circuited.
Wall mounting
Angle mounting
Corner mounting
INTERNAL LAYOUT AND SETTINGS (continued)
INTERNAL LAYOUT AND SETTINGS (continued)
DIP-SWITCH SETTINGS
DIP-SWITCH SETTINGS
Photo 3
DS1
Connection
Terminal
Settings
Dip-switch
Tamper
Switch
Battery
CR123A
Input stage
shielding
Infrared
sensor
Circuit board
retaining screw
9214
70000
_09_005