Once the device is connected to the panel's network, remove the battery and wait for 10 seconds.
Then press the
tamper
and re
install
the battery. Wait until the
LED
lights up. Once you release the
t
amper, the
LED
will go out. In this case, the range
test
will start.
During
range test
the device LED
blink
s every second. The duration of
range test
is 60-95 seconds. When it is finished the LED
goes off
and after 2 seconds the
test
result
is displayed
as follows:
Single
blink
:
Strong signal.
The device can be
safely installed
at this point.
Two
blink
s:
Normal signal.
The device can be safely
installed
at this point.
Three
blink
s:
W
eak signal.
It is
recommended
not to
install
the device
at this point. T
he
re will be
communication bettween the device and the control panel
but there will
be communication packet
s losses
.
Four
blink
s:
Out of range.
The
device
is forbidden to be placed in th
is point
.
Note
: As soon as the
test
procedure is started, it is suggested that the
device
c
over
will
be placed
directly in order to simulate the actual communication conditions. The environment must be also
adapted to the worst possible conditions (eg closed doors).
Finally, in case of
home improvements or renovation
, it is suggested
to perform a
range test
again
.
RANGE TEST
RANGE TEST
BATERRY REPLACEMENT
BATERRY REPLACEMENT
The detector checks its battery voltage and transmits the information to the panel.
When
the
control
panel displays a low battery indicator, the detector
will
continue to
operate
for at least 2 weeks.
N
evertheless
it is
recommended to replace the battery as soon as possible. This must be done by a
qualified technician
and
the control panel
must be
in
s
ervice mode
.
I s not allowed to discard batteries in to common trash bins, they must be discarded only
t i
in battery recycling points. Do not incinerate.
Page 4 of 5
9214
70000
_09_005
KL1
Figure 1
Example of con
nection
NC
external
magnetic contacts
with BS-470
The device can be connected to external magnetic contacts via the
KL1
terminal
block
(Figure
1
). If a magnetic field
is connected to this input, the device sends an alarm signal to the
control
panel.
If
the contact is not connected to an
external device, at the
cable
terminal
of the
KL1
, the
n
manufacturer
’s cable
must remain.
N
OTE:
The maximum distance of the external sensor cable is 3 meters !!!
CONNECTION WITH EXTERNAL MAGNETIC
CONTACTS
CONNECTION WITH EXTERNAL MAGNETIC CONTACTS