~ 6 ~
Some typical installations are shown as following
Sealed
door
to
access
chim-
ney
for
sweep-
ing
&
inspect-
ing.
FLUE
The
Flue
must
be
1.5mm
thick
rust
resistant
steel
and
3
times
it‘s
diameter
away
from
combust-
ible
materials.
For
example
150mm
Flue
Pipe
must
be
450mm
away
from
combustible
ma-
terials.
Access
door
Non-combustible
register
plate.
Minimum
1.5mm
thick
rust
resis-
tant
steel
or
heat
resis-
tant
board.
TOP
FLUE
OUTLET
If
the
chimney
is
not
sound,
i.e.
found
to
be
leaking
after
a
smoke
test
then
the
chimney
must
either
be
repaired
or
a
flexible
liner
may
be
used,
ensure
the
liner
is
the
correct
type
for
Multi-Fuel
applications.
See
diagram
below:
It
is
recommended
that
this
area
is
insulated
or
backfilled.
Flexible
Liner
SW
to
TW
Adapter
Maximum
Recommended
distance
is
1.5mtrs
of
connecting
fluepipe
to
existing
chimney
or
Twin
Wall
Class
1
system
Support
Bracket
for
Flexible
Liner.
Register
Plate
Support
Bracket
for
the
connecting
fluepipe
Vitreous
Fluepipe
with
stainless
access
door.