32
9-4 Combustion Analyzer Port
Flame
Flame
Burner
9 - START UP PROCEDURE
Look for BLUE fl ame
with slight YELLOW tips
evenly spaced around
burner
Verify Burner, Proper Operation
Inspect burner fl ame through Sight Glass. See
1.
fi gure 9-5.
Operate boiler through several heating cycles,
2.
including domestic hot water, if used. Verify proper
operation.
Reset control parameters to operating settings if
3.
adjusted to allow startup and operation test.
Follow instructions TO TURN OFF GAS TO APPLIANCE
4.
if boiler is not being placed into immediate operation.
Enter installer information on Warranty Registration
5.
Card.
Gather all instructions, manuals, wiring diagrams,
6.
warranty registration card and other supporting
information. Review with user and/or affi x in
conspicuous location adjacent to boiler.
Combustion Analyzer Port
WARNING
Asphyxiation hazard. Carbon monoxide is odorless,
tasteless, clear colorless gas, which is highly toxic.
Verify cap is fi rmly placed on combustion analyzer
port to prevent CO emission. Failure to do so could
result in death or serious injury.
!
9-5 Burner Flame