Dip Switch Adjustment Chart
For Input 0.55 USGPH TO 0.85 USGPH
SW1 - HEAT
POS.
SW2 - COOL
POS.
DIP Switch
Position
INPUT
DIP Switch
Position
AC Size
1
2
USGPH
1
2
(TON)
OFF
OFF
A
0.65
OFF
OFF
A
3.5
ON
OFF
B
0.85
ON
OFF
B
3.0
OFF
ON
C
0.75
OFF
ON
C
2.5
ON
ON
D
0.55
ON
ON
D
2.0
SW3 - ADJUST
POS.
SW4 - DELAY
POS.
DIP Switch
Position
CFM
DIP Switch
Position
INPUT
1
2
1
2
USGPH
OFF
OFF
A
0%
OFF
OFF
A
0.65
ON
OFF
B
(+)15%
ON
OFF
B
0.85
OFF
ON
C
(-)15%
OFF
ON
C
0.75
ON
ON
D
N/A
ON
ON
D
0.55
Table A-10 Direct Drive Blower Motor Setup - 1/2 HP ECM Variable Speed Constant CFM Motor
NOTE:
SW1 (HEAT) AND SW4 (DELAY) DIP SWITCHES MUST BOTH BE ADJUSTED ACCORDING TO INPUT (FIRING RATE).
SW2 (COOL): 1 TON is approximately equal to 400 CFM
SW3 (ADJUST)
Increase OR decrease CFM respectively
APPENDIX A - CHECK OUT AND ADJUSTMENTS
Table A-11 Direct Drive Blower Characteristics - 1/2 HP ECM Variable Speed Constant CFM Motor
Furnace Model
Blower
Motor HP
Motor FLA
∆T
LRFV 65 – 100
100-10T DD
1/2 HP ECM
7.7
55-85 °F
OIL HEATING
SW1 HEAT
DIP SWITCH POSITION
INPUT
[USGPH]
CFM WITH SW3-ADJ
DIP SWITCH POSITION A
CFM WITH SW3-ADJ
DIP SWITCH POSITION B
CFM WITH SW3-ADJ
DIP SWITCH POSITION C
A (1=OFF, 2=OFF)
0.65
1016
1168
864
B (1=ON, 2=OFF)
0.85
1430
1600
1216
C (1=OFF, 2=ON)
0.75
1229
1413
1045
D (1=ON, 2=ON)
0.55
828
952
704
CONTINUOUS FAN
SW2 COOL
DIP SWITCH POSITION
AC SIZE
[TONS]
CFM WITH SW3-ADJ
DIP SWITCH POSITION A
CFM WITH SW3-ADJ
DIP SWITCH POSITION B
CFM WITH SW3-ADJ
DIP SWITCH POSITION C
A (1=OFF, 2=OFF)
3.5
700
805
595
B (1=ON, 2=OFF)
3.0
600
690
510
C (1=OFF, 2=ON)
2.5
500
575
425
D (1=ON, 2=ON)
2.0
400
460
340