No 2 Fuel Oil Ratings
HTL Series
HTL-100
HTL-200
Riello Burner*
F3
F5
Unit Model
HTL-E1-*065-03
HTL-E1-*076-03
HTL-E1-*087-03
HTL-E3-*100-05
HTL-E3-*110-05
HTL-E3-*127-05
Firing Rate (USGPH)
0.55
0.65
0.75
0.85
0.95
1.10
Input (BTU/h)
77,000
91,000
105,000
119,000
133,000
154,000
Output (BTU/h)
65,000
76,000
87,000
100,000
110,000
127,000
Nozzle
0.50-70 W
0.60-70 W
0.65-70 W
0.75-60 W
0.85-60 W
1.00-60 W
Pump Press (PSI)
140
140
140
140
140
140
Turbulator Setting
0
0
0
3
3
3
Air Gate Adjustment
2.5
2.5
4
2
2.5
5
%CO2 for Factory Setting
10.0
11.5
10.5
11.5
10.5
10.0
%CO2 for AFUE
13.0
13.0
13.5
13.0
13.0
13.5
AFUE
85
84
83
85
84
83
Energy Star Approved
NO
NO
NO
NO
NO
NO
* These values are with the burner cover on
Beckett Burner
AFG
AFG
Unit Model
HTL-G2-*065-03
HTL-G2-*076-03
HTL-G2-*087-03
HTL-G2-*100-05
HTL-G2-*110-05 HTL-G2-*127-05
Firing Rate (USGPH)
0.55
0.65
0.75
0.85
0.95
1.10
Input (BTU/h)
77,000
91,000
105,000
119,000
133,000
154,000
Output (BTU/h)
65,000
76,000
87,000
100,000
110,000
127,000
Nozzle
0.50-70 B
0.60-70 W
0.65-70 W
0.75-70 W
0.85-70 W
1.00-70 B
Static Disk
3-5/8 U
3-3/8 U
3-3/8 U
2-3/4 U
2-3/4 U
2-3/4 U
Head
F0
F0
F0
F3
F3
F3
Low Fire Rate Baffle
Yes
Yes
Yes
Yes
No
No
Pump Press (PSI)
140
140
140
140
140
140
Air Band Setting
0
0
2
1
0
1
Air Gate Gate Setting
6
9
10
10
8
10
%CO2 for Factory Setting
10.5
11.5
11.8
11.5
11.5
12.0
%CO2 for AFUE
13.0
13.0
13.5
13.0
13.0
13.5
AFUE
85
84
83
85
84
83
Energy Star Approved
NO
NO
NO
NO
NO
NO
Carlin Burner
EZ-1 SELECT
EZ-1 SELECT
Unit Model
HTL-C1-*065-03
HTL-C1-*076-03
HTL-C1-*087-03
HTL-C3-*100-05
HTL-C3-*110-05
HTL-C3-*127-05
Firing Rate (USGPH)
0.55
0.65
0.75
0.85
0.95
1.10
Input (BTU/h)
77,000
91,000
105,000
119,000
133,000
154,000
Output (BTU/h)
65,000
76,000
87,000
100,000
110,000
127,000
Nozzle
0.50-60 B
0.50-60 B
0.60-60 B
0.65-60 B
0.75-60 B
0.85-60 B
Pump Press (PSI)
125
170
155
170
160
170
Head Setting
0.0
0.0
1.0
3.0
3.0
4.0
Air Gate Adjustment
30
35
50
55
65
65
%CO2 for Factory Setting
12.5
12.7
12.7
11.7
12.7
12.3
%CO2 for AFUE
13.3
13.2
13.5
13.5
13.5
14.0
AFUE
85
84
83
85
84
83
Energy Star Approved
NO
NO
NO
NO
NO
NO
(*) For administration only.
Содержание HTL-100
Страница 7: ...7 25 5 8 60 26 5 16 31 1 8 10 5 8 54 11 16 24 1 2 29 1 2 HTL 200 DIMENSIONS Dimensions are in inches...
Страница 26: ...26 Location of the 1158 120 Electronic Board HTL 100 and 200...
Страница 42: ...42 Page Left Intentionally Blank...