background image

General 

Please read this instruction carefully. It contains im-
portant information on safety, installation, use and 
maintenance of the AirCom Zentral. 
 
The manufacturer cannot be held responsible for 
problems occurring when the following instructions are 
not adhered to. The appliances must only be used for 
the function intended. 
 
 
 
 
 

Delivery, Packaging, Recycling 

 
To facilitate transport and handling, the ventilation unit 
and radiator cabinets are packaged separately. 
 
The packaging of your high-quality  OLSBERG  heat-
ing-ventilation system has been limited to the mini-
mum necessary for safe transport and is made en-
tirely of recyclable materials. 
 
The packaging and appliance parts have been 
marked according to present requirements and/or 
possibilities to allow the best possible disposal or re-
cycling at a future date. 
 
Packaging materials, replacement parts and appli-
ances or components to be scrapped must all be dis-
posed of correctly according to regulations. 
 

Disposal of old heaters 

Old electric and electronic devices often 
contain valuable materials. But they may 
also contain harmful ingredients which 
were necessary for their function and secu-
rity. In normal waste disposal or incorrect 
treatment they could be harmful to the en-
vironment. Please help to protect our envi-
ronment! Please do not add your old 
heater to normal waste in any case. Dis-
pose of your old heater according to the 
local regulations. 

 
 
 

 

Содержание AirCom Zentral

Страница 1: ...OLSBERG Instruction Manual OLSBERG AirCom Zentral Heating and ventilation system...

Страница 2: ...earances 28 On site preparation for installation 28 Flow and return pipework 28 External air ducting 29 Earthed plug and socket 29 Dimension diagrams 29 31 Assembly 32 34 Electrical connection 35 Circ...

Страница 3: ...d due to high air humidity and false ventilation can be prevented Steam and smells from bathroom and kitchen extracted Energy savings You will save heating costs as up to 70 of the heat from the extra...

Страница 4: ...ed in the cross flow heat exchanger by the ex hausted air Following this the pre heated air is drawn across a radiator The air is then heated up to room temperature level and is then passed through th...

Страница 5: ...e en tirely of recyclable materials The packaging and appliance parts have been marked according to present requirements and or possibilities to allow the best possible disposal or re cycling at a fut...

Страница 6: ...e position The ventilation appliance is designed to be mounted on an external wall as the fresh air and exhaust air ducting must be run to the outside Preferably a posi tion under a window should be c...

Страница 7: ...behind out of the wall or from below out of the floor for this type of connection If the heating pipes come sideways out of the wall the radiator is to be converted to a right hand connection to the...

Страница 8: ...ositions Fig 3 The left hand duct is always for the fresh air inlet and the right hand duct is always for the exhaust air outlet The knock outs in the wall mounting strip are larger than the external...

Страница 9: ...st air Floor Template accessory X Dimension of radiator connector angle fitting from middle of heating pipework to lower edge of radiator fittings Fresh air Exhaust air X Dimension of radiator connect...

Страница 10: ...figuration Air ducts Radiator connectors Heating pipes Connection from side Fig 6 Location of earthed socket Fresh air Exhaust air Floor Floor Lower edge of appliance inside thread Type Fresh air Exha...

Страница 11: ...able compen satory material must be placed at the fixing lo cations In the area of the air ducts PU foam or silicon must be used to provide a seal between the mounting strip and the wall Plugs and scr...

Страница 12: ...ng buildings OLSBERG offers suitable connect ing pipe sets as an accessory This pipework set makes the connection at the rear of the appliance to the connections on the right hand side of the applianc...

Страница 13: ...the appliance clearance to left side inner panel approx 15mm to right side panel of appliance approx 20mm Fix the screws at the top right and left of the fixing bracket firmly Connect the radiator fir...

Страница 14: ...ith a cable binder Only plug the device plug into the protected earthed socket when all mounting tasks have been concluded Circuit diagram 2 78 4536 0112 OFF Fan speed switch Electronics Printed Circu...

Страница 15: ...ing label for type 36 011 2 Spare parts By any queries concerning spare parts it is necessary to quote the type number and the fabrication number printed on the rating label We recommend that you note...

Страница 16: ...strip which is separately packed serves as a marker for the position of the air ducts during the construction phase Note The wall mounting strip is absolutely neces sary for fixing the appliance It c...

Страница 17: ...itch being over twisted Appliances that are not designed in according to the German Energy Saving Regula tions can have this screw removed so that the op erating mode Fresh Air summer operation in or...

Страница 18: ...etting 2 3 for continuous opera tion dependent on the size of the room If increased ventilation is necessary the fan speed should be tem porarily increased This naturally also increases the noise of o...

Страница 19: ...ectrical parts when the sealing panel is removed The ventilation module parts are to be removed in the following order 1 Remove the fresh air filter 1 2 Remove the cross flow heat exchanger 2 Make sur...

Страница 20: ...densate indicator tube and pull it forwards out of the appliance Then hold the end of the tube down below the level of the sump so that the condensate can drain off into another vessel Cleaning the ex...

Страница 21: ...be carried out by a competent electri cian Trouble shooting If the AirCom Zentral should not work for any reason please first check the following procedures Is the appliance plugged in Are the circui...

Страница 22: ...ir flow volume 20 60 m h Fan rating 8 38 W Sound pressure level 26 48 dB A Heat recuperation from exhaust air up to 70 Radiator heating rating at 70 55 C at 55 45 C 1005 W 633 W 1340 W 844 W 1675 W 10...

Страница 23: ...88 6 78 4636 0112 05 2011 Olsberg GmbH H ttenstra e 38 59939 Olsberg T 49 2962 805 0 F 49 2962 805 180 info olsberg com olsberg com...