4
.4.1
5
Height and angle adjustment of stand table
for d-Color MF450
1.
Measure the width of X on front and
back side.
Specifications: 4 ± 2 mm
2.
If X is out of the specified range,
remove two covers [1] from the legs
of the stand table.
3.
Loosen four screws [1] (two screws
each for the left and right) and adjust
the height of the stand. Tighten the
screws again.
X
A01GF2C515DA
A01GF2C566DA
[1]
[1]
A01GF2C567DA
[1]