Page | 10
2.3 Electrical Requirement:
After your stoner is mounted on a secure
foundation, you are ready to make electrical connections. The Stoner comes with a
complete electrical cabinet that is wired to all the electrical components, such as the
motors, reference keypads and dust hood light. Typical voltages would be 230V and
460V, three-phase, at 60 Hz, however other voltages can be accommodated.
Cable Size
AWG or kcmil
Terminal Torque Requirements
Lbs - in
N-m
Lbs - in
N-m
18-10
35
4.0
80
9.0
8
40
4.5
80
9.0
6 - 4
45
5.1
165
18.6
3
50
5.6
275
31.1
2
50
5.6
275
31.1
1
50
5.6
275
31.1
1/0 - 2/0
50
5.6
385
43.5
3/0 - 4/0
50
5.6
500
58.5
250 - 350
50
5.6
650
73.4
400
50
5.6
825
93.2
500
50
5.6
825
93.2
600 - 700
50
5.6
1000
113.0
Always ensure that all applicable national and local electrical standards are
followed during installation. For field connections, refer to the electrical schematics
provided inside of the electrical cabinet. When penetrating the electrical cabinet for
field wiring the electrician must enter the cabinet from the bottom. Failure to do this
will result in voiding the factory warranty on the electrical cabinet.
OVERCURRENT AND PROTECTIVE DEVICE (OCPD) Sizing.
Short circuit and
overload protection must be provided upstream of the power quality equipment.
Fused disconnects should be sized no less than 135% of the rated capacitor current.
To check for proper belt tension, first turn the machine off. Then apply pressure
to the side of the belt midway between the pulleys. The belts should deflect
Table 1: Electrical Requirements and Precautions
Содержание Hi-Cap N Series
Страница 6: ...Page 6 ...
Страница 34: ...Page 34 this section intentionally left blank ...
Страница 35: ...Page 35 V Appendices Appendix A Maintenance and Basic Troubleshooting ...
Страница 41: ...Page 41 Appendix B The ABB ACS380 VFD ...
Страница 42: ...42 P a g e The ABB ACS380 VFD B 1 Getting to know the VFD Keypad Figure 16 VFD keypad overview ...
Страница 43: ...43 P a g e Figure 17 VFD keypad display ...
Страница 44: ...44 P a g e Figure 18 VFD keypad status line ...
Страница 47: ...47 P a g e A 2 Programming the VFD from the Keypad Figure 20 Changing VFD parameters ...
Страница 49: ...49 P a g e ...
Страница 50: ...50 P a g e Appendix C Timer manual ...
Страница 51: ...51 P a g e C 1 Getting to know timer operation ...
Страница 52: ...52 P a g e C 2 Timer dip switch selection ...
Страница 53: ...53 P a g e Appendix D Electrical and Dimensional drawings ...
Страница 54: ...Page 54 D 1 Electrical drawings ...
Страница 55: ...55 P a g e ...
Страница 56: ...56 P a g e ...
Страница 57: ...57 P a g e D 2 DIMENSIONAL LAYOUT DRAWINGS ...
Страница 58: ......