HP-400P HORIZONTAL BAND RESAW -36-
Connecting to Dust Collector
To be effective, the dust collection system that you connect to the resaw must be able draw at least 1000
CFM at the point where you connect your hose to the machine.
Note—This number is an approximation and has been provided for estimation purposes only.
To connect the resaw to a dust collector
:
Attach a 4" dust hose to the dust port as shown in below, and be sure to tighten the hose clamp to ensure a
snug fit.
Connecting to Power Source
If you have performed all of the previous setup instructions, you are ready to connect the resaw to the power
source.
To connect the resaw to the power source
:
1. Read through Section 3
:
Circuit Requirements to double-check that your setup follows the safety and
circuit requirements, and that the power cord you have chosen meets the minimum requirements for this
machine.
2. Open the electrical panel on the machine.
3. Connect the cord to the machine circuit breaker terminals.
4. Close and latch the electrical panel on the machine.
5. Shut off the main power at the circuit breaker and install the cord to the disconnect switch.