8. Set Low Speed Limit
This function defines the speed level which is considered abnormal for the machine.
When the Controller starts the table movement up or down, and the table does not
move, or moves with a speed lower than defined, it stops the machine and displays.
E n G i n E
F A u l t
Press
to
clear.
To Set low speed limit:
1
9
F
Step 1: Press
Display
F A u l t
....[default]
55
Step 2: Enter the low speed level 0 to 99
0 = Machine test is disabled
1 = Very low
:
:
99 = High