22
4. OPERATION
4.1. Digital Thermostat Models
PYOL1H0531
PY0L2K0532
Light Bu on
Defrost
Set/Change
On/Off
1
7
2
3
4
5
6
Led
1
2
3
4
5
6
7
Func on
Compressor
Fan
Defrost
Auxiliary Output
Clock (RTC) (some models)
Alarm
Algorithms
The opera on of the equipment is totally controlled by the digital thermostat, which allows for the
selec on of temperature and controls the opera on of the ligh ng using the bu on
(models with
.
glass door and opaque door with ligh ng).
Connect the equipment to the mains. If "OFF" appears in the digital display, press the ON/OFF bu on
for 3 seconds.
It is necessary to wait +/- 3 minutes for the compressor to start a er the cabinet is connected to the
mains.
The digital thermostat controls the temperature from +1°C to +10°C on the posi ve storage cabinet
models, and from -16°C to -22°C on the nega ve storage cabinet models. In sub-zero models, the
temperature can be adjusted between -2,5°C and +10°C.
The thermostat is locked at the factory, allowing only the set point to be adjusted. To do this, press the
"Set" bu on, a er the set value starts blinking, get to the desired value with the
bu ons
“
▲
” and “
▼
”
and press the "Set" key again to set the value.
The temperature shown on the display is the equipment's internal temperature.
The equipment's noise level is less than 70dB.
Note:
The equipment's difference in temperature (difference between maximum and minimum
permissible temperature) is set at 3°C at the factory for the refrigerated counters and backbar coolers,
in models BRS, BRG, BPP, BPG, and FGB, the difference is 4°C, and in models ARV 36; ARV 66, ARV 150,
ARV 350, and ARV 450 the difference is 2°C.
When fully loading the cabinet, it is possible for the alarm to go off a er 2 hours if it has not reached the
set temperature, and "Hi" is visible in the display. Press the "mute" bu on to turn the alarm off and wait
12 hours for the temperature to stabilize.
If the set temperature has not been reached within this me, please contact our technical service. The
following messages may appear on the thermostat:
Содержание Marecos Horeca ARV 36