![Olimpia splendid PHENIX E Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/olimpia-splendid/phenix-e/phenix-e_instructions-for-use-and-maintenance-manual_3788853097.webp)
PHENIX E INVERTER
ENGLISH
EN - 41
LC 05
frequency limit caused by voltage
LC 03
frequency limit caused by current
LC 02
frequency limit caused by tP
LC 01
frequency limit caused by t3
LH 00
frequency limit caused by t2
LC 06
frequency limit caused by PfC
LH 07
frequency limit caused by remote controller
NA
no malfunction or pretecion
FOR EACH ERROR:
Switch off the unit and wait 2 minutes before restarting it, if the problem persists, please contact the
assistance centre.
5.2 - OTHER ERROR
The display board may show a garbled code or a code undefined by the service manual. Ensure that this
code is not a temperature reading.
test the unit using the remote control.
- if the unit does not respond to the remote, the indoor PCB requires replacement.
- if the unit responds, the display board requires replacement.
Содержание PHENIX E
Страница 2: ......
Страница 7: ...min 120mm min 150mm min 120mm min 2300mm 1 3 5 4 7 8 2 4 7 3 5 6 9 7 D H E F C B G A I M L N 7 C B A...
Страница 8: ...10 12 11 13 90 14 16 15 D E F C B A 6 5 5 A A B 2 2 1 1 3 17...
Страница 9: ...21 22 23 26 25 20 OK b a 18 20 19 20 27 min 1500mm 24...
Страница 11: ...38 39 37 1 3 4 8 9 6 2 5 4 7 10 11 12 34 36 35 click 40 41...
Страница 12: ...44 46 45 47 a b 42 43...
Страница 309: ......
Страница 310: ......
Страница 311: ......
Страница 312: ...263242A...