![Olimpia splendid ClimaPiu 12 HE HP Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/olimpia-splendid/climapiu-12-he-hp/climapiu-12-he-hp_manual-for-installation-instructions-for-use_731069019.webp)
54
The connection cordons must be of the type H07-RR-F with
outer diameter of 14,5 mm and they must have the following
section (the under indicated values refer to a maximum
lenght of the lines of 15 meters.
Split appliances
Cable
1
2,5
2,5
2,5
2,5
2
2,5
2,5
2,5
2,5
3
—
1,5
—
1,5
4
1,5
1,5
1,5
1,5
5
2,5
2,5
2,5
2,5
IMPORTANT: If the cables have to be walled then install
raceways to facilitate their removal in the future.
SENSOR CONNECTION WARNING: Do not connect the
sensor to live terminals, as this would irreparably damage
the electronic board.
4
Starting the appliance and topping up the charge
Before turning on the appliance it is essential to make sure
that:
- the input voltage remains within the limits specified in
paragraph 2.2 "Technical particulars". The appliance must
not be turned on if the voltage is greater or less than that
specified as it could undergo serious damage not covered
by the garantee.
- the cooling charge inserted in the external unit within the
factory has been introduced into the installation. If the
charge has been introduced, the faucets on the external
unitis gas and liquid connections should be open.
- the charge has not leaked due to the appliance being left
off immediately after installation is completed. To carry
out this operation it is necessary to unscrew the cap on the
service valve which can be found on the external unitis
gas line connection (or on one of the external unitis gas
line connections in the case of the Multisplit appliance)
and see if the circuitis pressure corrisponds at least to the
saturation pressure at atmospheric temperature. If there
is a possibility that a part of the charge has leaked it will
be necessary to check the charge according to the modes
indicated in the Technical Handbook.
- the air can circulate without difficulty through the internal
(or the internal units in the case of Multisplit) and external
units.
The applianceis general disconnector can then be closed as
can its circuit breaker which is found on the right hand side
at the inside of the upper door and check that the consoleis
green LED on the left lights up. Then, following the instructions
enclosed in the Useris Instructions Handbook, turn the
appliance on using the remote control.
A couple of minutes after the appliance has been turned on,
the compressor is activated and the internal unit starts to
give out cold air.
In the case of hot pump appliances, one must also check
that the appliance starts to pump hot air after switching the
working mode. One must not forget that once the appliance
Fig. 22
HEAT PUMP