Advanced Programming Options
FEATURE
PARAMETER
DESCRIPTION
ICON
VALUE RANGE
DEFAULT
VALUE
Min
Max
MODE
1
This is the selectable Mode:
Current Mode (and
new when changed)
-
-
0
0. Off
2. Cooling
3. Heating
HOME ANTIFREEZE
2
This parameter enables the Home Antifreeze
option when the system is Off:
Antifreeze
1
2
1
1. NO. Disable
2. YES. Enable
HOME ANTIFREEZE
T°
3
Home Antifreeze threshold Temperature value
°C
6°C
12°C
6°C
ADJUST T° Z1
4
Water set point adjustment for
room temperature at
6*
zone
°C
-5°C
+5°C
0°C
FREQ REDUCT
MODE
5
This code gives information whether Silence
mode / Frequency Reduction/ Night mode is
active
1
2
1
1. Not Active
2. Active
FREQ REDUCT
6
Value of the frequency reduction in % of CDU
50%
100%
75%
ROOM MODE
7
6*
will display this parameter
Arrow depending by
Room mode
1
3
1
1. Home
2. Sleep
3. Away
CTRL ROOM SP Z1
8
This code is the control Room Set-point
determined by pressing the Home, Sleep, Away
buttons
°C
12°C
38°C
20°C
ROOM AIR T° W1
9
This is the room air Temperature read by
the internal
6*
Thermistor
°C
-20°C
50°C
RH SENSOR VALUE
10
This is the relative Humidity value from the
sensor
%
0
100
OUTDOOR T°O
11
Outdoor Temperature measured by the TO
sensor (reading value).
°C
-30°C
90°C
GMC OAT
12
OAT from
$%6
board
°C
-20°C
65°C
TROOM SENSOR
ADJ Z1
13
Temperature sensor adjustment to recover bad
user interface positioning error
°C
-5°C
5°C
0°C
DAY PERIOD
14
This Parameter says about the periods per day
will be available for the scheduling:
2
6
4
1. 2
2. 4
3. 6
HOME HEAT T°
15
HOME Temperature set-point in Heating mode
12°C
38°C
20°C
°C and the arrow for
Home
HOME COOL T°
16
HOME Temperature set-point in Cooling Mode
12°C
38°C
24°C
°C and the arrow for
Home
SLEEP HEAT T°
17
SLEEP Temperature set-point in Heating Mode
12°C
38°C
18°C
°C and the arrow for
Sleep
SLEEP COOL T°
18
SLEEP Temperature set-point in Cooling Mode
12°C
38°C
26°C
°C and the arrow for
Sleep
AWAY HEAT T°
19
AWAY Temperature set-point in Heating mode
12°C
38°C
15°C
°C and the arrow for
Away
AWAY COOL T°
20
AWAY Temperature set-point in Cooling Mode
12°C
38°C
28°C
°C and the arrow for
Away
USER ROOM SP Z1
21
Room set point
°C
12°C
38°C
20°C
FAULT CODE
22
Fault codes will be scrolled @ 1 second
3
31
FAULT HISTORY
23
Stores the recent 4 fault codes
3
31
The parameters which are Read-Only and are not editable, Key pad lock ( ) icon will be displayed on the screen for those parameters. The list of Read-
Only parameter numbers are given below.
Parameter Number: 7, 8, 9, 10, 11, 12, 21, 22 and 23
Features Table