25
Chapter 7 | Specifications
Detector
Dimensions
118*110*60 mm
Ingress protection
IP65
Enclosure ABS
Inlet and outlet cable
2 cable gland M16, diameter 4 to 8 mm
Type of cable
Type MPI-22A
Power supply
12-30V
Consumption
Electrochemical sensor : 2.5mA in normal
operating @ 24V
Catalytic sensor : 50 mA in normal operating@ 24V
Status indication during
calibration
LED red/green
Calibration
Automatic, no need to open the sensor due to a
gas introduction device equipped with a magnetic
switch, or with a potentiometer inside of the case.
Calibration gas is set in the detector
Sensor replacement
Sensor replacement switch on the interior of the
CPS 10 case.
Detection of sensor
Humidity 15-90%
RH
Storage conditions
4 – 20 °C
20 – 60 % RH
1 bar ± 10 %
6 months maximum
Certification
CEM EN 50270 (type 1)