9
LIGHTING INSTRUCTIONS
1.
STOP! Read the safety information above on this sheet.
2.
If using a grate, remove control access panel below grate.
3.
Push in gas control knob slightly and turn counter clockwise 4— to
“OFF”
NOTE: Knob cannot be turned from “Pilot to “OFF” unless the knob is
pushed in slightly. Do not force.
4.
Wait five minutes to clear out any gas. Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B” in the safety information above on this
page. If you don’t smell gas, go to the next step.
5.
Push in gas control knob slightly and turn clockwise —, to “Pilot.
6.
Depress the control knob fully and push spark igniter button several times to
light the pilot.
7.
Continue to hold the control knob in for about 60 seconds after the pilot is
lit.
NOTE: If the pilot extinguishes, repeat steps 1,2,3 and 4.
8.
Turn the control knob clockwise to “ON”.
9.
Adjust the HI-LO flame control knob to desired setting.
NOTE: *lf the unit is hot, wait
5
minutes to relight the pilot.
*If control knob does not pop up when released STOP, and immediately call
your service technician or gas supplier.
10.
Replace control access panel below grate.
11.
Wall switch or remote may now be used to turn main flame ON and OFF.