Old Salem Hearths BRWR400I 6V39 BV3ON Скачать руководство пользователя страница 2

 

 

WARNING:

 If the information in this manual is not followed exactly, a fire or 

explosion may result causing property damage, personal injury or loss of life. 

 

 

 

The Old Salem Regency coal set is a ventless appliance consisting of an 
integrated burner control and a simulated coal fire. There are no loose parts 
nor any field assembly required. 

MODELS 

SIZE 

INCHES TO NON 

COMBUSTIBLE

MINIMUM FIREPLACE 

SIZE 

R400IGV36 BV3ON  19.5”W F, 17.5”W 

B, 
12” D, 14.75” Fl 

0 Sides, 0 Back, 
0 Floor. 

19.5”W F, 17.5” W B, 
12” D., 14.75” H 

BRWR400I 

GV36BV3ON 

19.5” W F, 17.5” W 
B, 
12” D, 14.75” H 

0 Sides, 0 

Back, 

Floor 

19.511 WF, 17.5” W 8, 
12” D, 1475” H 

WR400I 0V39 

BV3ON 

16” W F, 14” W B 
,l2” D,14”H 

0 Sides, 0 Back, 
0 Floor 

16” W F,14” W 8,12” D, 
14”H 

BRWR400I 6V39 

BV3ON 

16” W F, 14” W B 
,12” D., 14” H. 

0 Sides, 0 Back, 
0 Floor 

16” W F, 14W B ,12” D, 
14” H. 

  
Maximum BTU for Natural Gas - 13,400 intake 
 
Maximum BTU for Natural Gas Bedroom unit - 10,000 intake 
 
Minimum BTU for Natural Gas - 9,000 intake

 

 
 
 

INTRODUCTION 

The  Old  Salem  Regency  coal  set  is  a  ventless  heater  appliance  consisting  of 
integrated  burner  controls  and  a  simulated  coal  fire.  There  are  no  loose  parts  or 
any  field  assembly  required.  It  is  intended  for  installation  in  a  masonry  or  non-
combustible fireplace only. When installed in an existing fireplace, the flue must be 
blocked to prevent down drafts from disturbing the flame patterns and the chimney 
must  be  capped  to  prevent  potential  water  damage  to  the  appliance.  See  the 
following section for additional requirements. 

 

1) GENERAL INSTRUCTIONS - IMPORTANT SAFETY INFORMATION 

 

WARNING: This appliance is for installation only in a solid fuel-burning fireplace. 
 
WARNING: Before installing in a solid fuel-burning fireplace, the chimney flue and 
firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified 
chimney cleaner.

 

Содержание BRWR400I 6V39 BV3ON

Страница 1: ...a neighbors phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agen...

Страница 2: ...Maximum BTU for Natural Gas 13 400 intake Maximum BTU for Natural Gas Bedroom unit 10 000 intake Minimum BTU for Natural Gas 9 000 intake INTRODUCTION The Old Salem Regency coal set is a ventless hea...

Страница 3: ...ever burn solid fuels in a fireplace where a gas coal set is installed e This unit complies with ANSI Z21 11 2 Unvented Heaters f The installation must conform with local codes or in the absence of lo...

Страница 4: ...q DO NOT TAMPER WITH THE PILOT LIGHT SAFETY SYSTEM r If heater shuts off do not relight until you have provided fresh air If heater keeps shutting off have it serviced Keep burner and control compartm...

Страница 5: ...ther openings b The Old Salem coal set has been equipped with an oxygen depletion system to prevent reduction of the oxygen level in the installation room from reaching a level below 18 percent The ab...

Страница 6: ...clean g WARNING any change to this heater or its controls can be dangerous h This appliance is intended for supplemental heating 5 NATURAL GAS PIPING a The installation must conform with local codes...

Страница 7: ...ipe be run through the masonry into the firebox area Using an approved flexible gas hose connect to line from the fixed pipe to the gas input to the appliance All pipe work going through masonry shoul...

Страница 8: ...touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier...

Страница 9: ...the next step 5 Push in gas control knob slightly and turn clockwise to Pilot 6 Depress the control knob fully and push spark igniter button several times to light the pilot 7 Continue to hold the con...

Страница 10: ...d the control knob down for 60 seconds 4 Contact your service technician or gas supplier to replace the defective unit The flame level has been preset for relatively small changes in BTU level At firs...

Страница 11: ...11 Note Basket is delivered with Jumper wire installed It must be removed for external switch or remote control to work Remove factory jumper when installing remote control...

Страница 12: ...n under water Immediately call a qualified service technician to inspect the appliance and determine if the appliance must be returned to the manufacturer for repair and calibration 11 TROUBLE SHOOTIN...

Страница 13: ...NOTE In the interest of product development and the introduction of any new relevant mandatory gas requirement the manufacturer reserves the right to modify and amend the appliance s and instructions...

Отзывы: