![Okina USA SEIMW36T-V53DN Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/okina-usa/seimw36t-v53dn/seimw36t-v53dn_operation-manual_3699032011.webp)
ALARM SETTING
BACK
EXIT
-------------------------------------
ALARM NUMBER
001
ALARM ACTION
TOUR
ACTIVATE AUX
NONE
ALARM PRIORITY
HIGH
ALARM NUMBER:
ALARM ACTION:
ACTIVATE AUX:
ALARM PRIORITY:
BACK:
supports up to 7 alarm ( 7 input & 1output pre-wired)
Setting for PRESET, SCAN, TOUR, PAT 1-4, or NONE, if the camere in alarm position.
Setting Alarm Output, when Alarm is activate. Select between AUX1, AUX2 (not connected)
or BOTH.
Priority when multiple alarms are triggered.
Move to previous menu.
AUX2
AUX1
ALARMAS
7
6
5
4
3
2
1
GND
Alarm input 1to 7
Common port
Alarm output 1
Alarm output 2
Alarm Connection
on Backboard
ALARMS
BACK
EXIT
RESUME
OFF
SEQUENCE
002
RESET DELAY
020
ALARM CONTACT
N/C
ALARM SETTING
ARM SETTING
→
→
RESUME:
SEQUENCE:
RESET DELAY:
ALARM CONTACT:
ENABLE WINDOW:
ALARM SETTING:
ARM SETTING:
Continue the function on the camera , if it was setting before the alarms.
How long the camera stay in Alarm position.
Setting between N/C (normal Close) or N/O (normal Open).
Activate the masking window
expanded Alarm setting
expanded Alarm setting
Alarms
Alarms
Alarm Setting
ARM SETTING
BACK
EXIT
--------------------------------------
DAY
SUN
ARM STATE
OFF
ARM TIME
N/A
UNARM TIME
NA
DAY:
ARM STATE:
ARM TIME:
UNARM TIME:
Arm setting for weekdays
Arm or disarm the alarm for the selected weekday
Scheduled alarm time
Disarm time.
Alarms
Arm Setting
LANGUAGE
--------------------------------------
LANGUAGE
ENGLISH
BACK
EXIT
LANGUAGE:
Selectable between available languages.
Language
OSD
English
8