ML63611 User’s Manual
Chapter 11 Melody Driver (MELODY)
11 – 5
OPTION B (D): 1.5 V (3.0 V), With regulator
circuit for LCD bias
OPTION A (C): 1.5 V (3.0 V), Without regulator
circuit for LCD bias
11.4.1 Tempo Data
Tempo data defines the basic tone length. Tempo data is set in the tempo register (TEMPO).
The tempos (number of counts per minute) set by TEMPO are shown in Table 11-1.
Table 11-1 Melody Tempo
TEMPO
TP3–0
TP3
TP2
TP1
TP0
Tempo
0H
0
0
0
0
= 480
1H
0
0
0
1
= 480
2H
0
0
1
0
= 320
3H
0
0
1
1
= 240
4H
0
1
0
0
= 192
5H
0
1
0
1
= 160
6H
0
1
1
0
≅
137
7H
0
1
1
1
= 120
8H
1
0
0
0
≅
107
9H
1
0
0
1
= 96
AH
1
0
1
0
≅
87
BH
1
0
1
1
= 80
CH
1
1
0
0
≅
74
DH
1
1
0
1
≅
69
EH
1
1
1
0
= 64
FH
1
1
1
1
= 60
Содержание ML63611
Страница 9: ...Chapter 1 Overview...
Страница 33: ...Chapter 2 CPU and Memory Spaces...
Страница 42: ...Chapter 3 CPU Control Functions...
Страница 49: ...Chapter 4 Interrupt INT...
Страница 62: ...Chapter 5 Clock Generator Circuit OSC...
Страница 71: ...Chapter 6 Time Base Counter TBC...
Страница 75: ...Chapter 7 Timers TIMER...
Страница 99: ...Chapter 8 100 Hz Timer Counter 100HzTC...
Страница 103: ...Chapter 9 Watchdog Timer WDT...
Страница 108: ...Chapter 10 Ports INPUT I O PORT...
Страница 140: ...Chapter 11 Melody Driver MELODY...
Страница 152: ...Chapter 12 Serial Port SIO...
Страница 179: ...Chapter 13 LCD Driver LCD...
Страница 200: ...Chapter 14 Battery Low Detect Circuit BLD...
Страница 204: ...Chapter 15 Power Supply Circuit POWER...
Страница 215: ...Chapter 16 A D Converter ADC...
Страница 238: ...Appendixes...
Страница 271: ...ML63611 User s Manual First Edition May 2001 Second Edition June 2001 2001 Oki Electric Industry Co Ltd PEUL63611 02...