45584901TH Rev.1
4-6 /
Oki Data CONFIDENTIAL
(5) When the adjustment has finished normally, press the [OK] button to have the adjustment
results reflected.
(To cancel the reflection of adjustment results, press the [CANCEL] button.)
In the case of an abnormal ending, “ADJUSTMENT ERROR” is shown.
Press the [CANCEL] button to clear the error display. When it is cleared, the control panel
display will return to the ready state. Then, check if the patch chart on the original glass is
placed in the wrong direction or if it is placed inclined on the original glass, and then repeat
step (3) and afterward.
Remarks:
To select the paper type for the automatic gamma adjustment in user calibration, change the
code below to “1”. (copy/print)
Code
Remarks
08-9059
0: No paper selecting buttons displayed
1: Paper selecting buttons displayed. (For both Copy and Printer)