7. TROUBLESHOOTING PROCEDURES
No. Category
PJL
Status
Code
Error Warning
Description
10
Error
40967
1
2
3
4
5
Please check data.
Program Data Receive Error
<%DLCODE%>
An error has happened
while the printer is receive-
processing the NIC download
data.
%DLCODE%
1: File size error
2: Check-sum error
3: Invalid printer model number
4: Invalid module I/F version
5: Invalid FAT version
11
Error
40967
1
2
3
4
5
Wait a moment.
Program Data writing ...
The printer is writing the NIC
download data.
12
Error
40967
1
2
3
4
5
Power OFF/ON
Program Data written OK.
The printer finished writing the
NIC download data.
13
Error
40967
1
2
3
4
5
Please check data.
Program Data Write Error
<%DLCODE%>
An error has happened while
the printer is writing the NIC
download data.
%DLCODE%
1: Memory allocation error
2: Download file error
3: Device allocation error
4: No device space
5: File writing failure
6: CU-F/W mismatch
14
Normal
10798
1
2
3
4
5
SIP update in progress.
Indicates that downloading the
SIP firmware data.
No. Category
PJL
Status
Code
Error Warning
Description
15
Error
-
1
2
3
4
5
Please check data.
Program Data Write Error
<%DLCODE%>
Indicates that an error has
happened while writing the
SIP download data.
%DLCODE%
1: Data transfer error
2: No device space
3: Check sum error
4: Chip detection error
5: Chip erace error
6: Chip writing error
7: Chip verify error
8:
Data error
(Product code is wrong e.t.c.)
9: Data size error
16
Normal
10795
1
2
3
4
5
%RDYMSG%
Indicates that the unit date is
being updated by using PJL
command.
17
Normal
10796
1
2
3
4
5
%RDYMSG%
Indicates that the requested
process is finished.
"Passed" is displayed, if
the process is completed
correctly.
"Failed" is displayed, if the
process is finished with an
error.
This indication disappear
automatically after it displayed
for three seconds.
18
Normal
10759
1
2
3
4
5
Wait a moment.
Executing maintenance.
Executing maintenance.
While this status occurs, panel
is locked.