44952001TH Rev.2
5-11
Oki Data CONFIDENTIAL
5. MAINTENANCE MENUS
Option
Adjustment
Section in
Maintenance
Utility
Operating
Manual
Operation from
operator panel
(section in this
maintenance
manual)
10 Destination/
PnP informa-
tion setup
Sets and checks the printer's (CU)
destination, device identification and
USB identification.
2.4.1.2.9
5.4.3
11 Password
initialization
Initializes a Password.
2.4.2.2.13
12 Network
log storage
function
Stores a network log file.
2.4.2.2.14
Unavailable
13 PU log file
storage
function
Stores a PU log file
2.4.2.2.16
Unavailable
14 Send to file
Send the specify file.
2.4.1.2.15
Unavailable
15 Set FAX
Parameter
Set the FAX parameter.
2.4.2.2.18
Unavailable
16 Consumable
counter
display
Checks the current consumable
counter values.
2.4.1.3.1
5.1 (ENG STATUS
PRINT)
17 Menu setting
check
Displays the menu settings set on the
printer (CU).
2.4.1.3.2
Print a configuration
report (Menu
Map) (refer to user
documentation).
18 Printer
information
check
Checks the MAC address and each
firmware version.
2.4.1.3.3
Print a configuration
report (Menu
Map) (refer to user
documentation).
19 CPU and
Memory
value check
Checks the information on the printer's
installed (CU) CPU and memory.
2.4.1.3.4
Print a configuration
report (Menu
Map) (refer to user
documentation).
20 Test print
Executes the local print function and
sends a specified file.
Purpose: To check the printer for
operation it performs solely and send a
download file.
2.4.1.4.1
Perform local
printing (refer
to System
Specification).
21 Switch scan
test
Executes the switch scan test.
Purpose: To check each sensor for
operation.
2.4.1.5.1
5.4.3
Option
Adjustment
Section in
Maintenance
Utility
Operating
Manual
Operation from
operator panel
(section in this
maintenance
manual)
22 Motor clutch
test
Executes the motor clutch test.
Purpose: To check each item, such as
a motor or clutch, for operation.
2.4.1.5.2
5.4.4
23 Color
registration
adjustment
test
Executes the color registration
adjustment test.
2.4.1.5.3
5.4.6
24 Density
adjustment
test
Executes the density adjustment test.
2.4.1.5.4
5.4.7
25 Auto density
adjustment
control
parameter
setting (never
use this
option)
Sets an auto density setting control
parameter.
Never use
this option.
5.4.8
26 Counter
display
Checks the consumable, continuous
consumable and waste toner counters.
2.4.1.5.6
5.4.9
27 Local
parameter
setting
Switches between the Factory and
Shipping modes and checks the status
of the fuse.
2.4.1.5.7
5.4.10
28 Engine
parameter
setting
Makes an engine parameter setting.
2.4.1.5.8
5.4.11
29 Media
transfer
parameter
setting
Makes a print media transfer parameter
setting.
2.4.1.5.9
5.4.11
Note!
Do not operate or set options added with ‘Never use this option,’ or a
malfunction is potentially caused.
Before starting the maintenance, please disable MPS mode setting when the
unit activate MPS mode as Enable. The condition of MPS mode is displayed
on the header of Configuration pages as "MPS : OFF/ON".