29
7
-
2
. Frequency adjustment 2
■
When using frequency counter
1. Press and hold SW1 and enter "Setting" from the "function selection menu".
2. Connect the closer end of CN2 on the SDR-3A board to the frequency
counter. Please take GND from BNC connector etc.
3. At this time, since the test signal of 10 MHz (40 mVpp) is output from CN2,
adjust so that the frequency counter display will be 10MHz.
4. Turn RE2 while "1. Freq Adj" is selected, the frequency becomes 10MHz.
Frequency adjustment is in ppm, it's 10Hz at 10MHz.
5. Press and hold SW1 to return to the "function selection menu" screen and
the setting is written to Flash.