QUICK START GUIDE OJ-DV-HMI-35T 

Technical data

Supply voltage ....................................................................................................................... 24 VDC +/-10%  
Cable dimensions ....................................................................................................................max. 0.75 mm

2

 

Relative humidity .....................................................................................................0–95% (non-condensing) 
Operating temperature .......................................................................................................... −10°C to +40°C 
Enclosure rating ..................................................................................................................... IP21 (EN 60529)
Port ...................................................................................................................................... 1 x RJ12 (RS485)
........................................................................................................................................10 x screw terminals
Dimensions (without bumper cover) ................................................................................... 80 x 121 x 42 mm
Dimensions with bumper cover ................................................................................. 86.1 x 127.1 x 50.9 mm 
Max. power consumption ...................................................................................................................900 mW

Service and maintenance

The OJ-DV-HMI-35T touch panel contains no parts that require service or maintenance. Contact your 
supplier in case of a problem.

Disposal and environmental protection

Help protect the environment by disposing of the packaging and redundant products in an 
environmentally responsible manner. 

Products marked with this symbol must not be disposed of with household waste, but must 
be delivered to a waste collection centre in accordance with current local regulations. 

Liability

OJ cannot be held liable for any errors in catalogues, brochures or other printed material. OJ reserves 
the right to alter its products without notice. This also applies to products already on order, provided that 
such alterations can be made without requiring subsequent changes in specifications already agreed. 
All trademarks in this material are the property of the respective companies. OJ and the OJ logotype are 
trademarks of OJ Electronics A/S. All rights reserved.

CE marking  

OJ Electronics A/S hereby declares under sole responsibility that the product complies with the following 
EU Directives:  
EMC – Electromagnetic compatibility: 2014/35/EU  
RoHS – Restriction of the use of certain hazardous substances in electrical and electronic equipment: 
2011/65/EU  

Applied standards

EN 61000-6-2 and EN 61000-6-3 Electromagnetic compatibility (EMC)

Содержание OJ Drives OJ-DV-HMI-35T

Страница 1: ...67817A 08 19 SJR 2019 OJ Electronics A S QUICK START GUIDE OJ DV HMI 35T OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS ...

Страница 2: ... Modbus cable with two RJ12 6 plugs on each end used to connect to the OJ DV See fig 2 1 Active mode When connected to the OJ DV s Modbus port A the OJ DV HMI 35T will function as a Modbus Master Other forms of Modbus Masters such as OJ Air2 or BMS controls cannot be connected at the same time Passive mode Connected to Modbus OJ DV s port C the OJ DV HMI 35T will become a Modbus Slave The hand ter...

Страница 3: ...atus Readout of the operating parameters of the connected OJ DV Drive setup Application parameter settings User settings Setup of user settings I O Configuration of digital inputs and outputs Warnings and Alarms Readout of the active warnings and alarms of the connected OJ DV Modbus Modbus settings for the connected OJ DV Configuration Configuration of motor and fan Software Readout of software ve...

Страница 4: ... setting is set at the factory and is Address 0 Baud rate 115 2 kbps Parity Even Stop bits 1 It is possible to change the alternative Modbus setting using Modbus register The OJ DV automatically detects whether communication is via the default or alternative Modbus setting After 10 seconds of no communication on the default setting the DV will search for the alternative setting and vice versa Chan...

Страница 5: ...ting onto a flat surface using a screw The rear of the HMI unit has a keyhole shaped hole for hanging the unit on a screw that has been screwed into the flat surface see Fig 1 1 Use a screw with a diameter that is not greater than 3 5 mm and a length that is not longer than 9 mm Fitting onto a flat metal surface using magnets The black protective cover contains two magnets The HMI can be fitted on...

Страница 6: ... products in an environmentally responsible manner Products marked with this symbol must not be disposed of with household waste but must be delivered to a waste collection centre in accordance with current local regulations Liability OJ cannot be held liable for any errors in catalogues brochures or other printed material OJ reserves the right to alter its products without notice This also applie...

Отзывы: