6.3 Electrical data
Power connection, VSi 6–14
Heat pump
VSi 6
VSi 8
VSi 10
VSi 12
VSi 14
Mains connection
400 V 3~ 50 Hz
Starting current
A
15
17
23
32
35
Operating current at
+35/+55 °C
A
2.68/
3.25
3.28/
4.18
4.33/
5.52
4.92/
6.41
6.81/
8.10
Supply cable size
(bivalent system in
brackets)
mm
2
5 x 2.5*
(5 x 6)
Supplementary electric
immersion heater output
kW
6
Soft starter as standard
Yes
Load guard
Optional
Compressor motor
protection circuit breaker
ratings
A
6
6
7
9
10
*If a long run of supply cable is required, the recommended minimum cable size is 5 x 6 mm
2
.
Power connection, VMi 6–17
Heat pump
VMi 6
VMi 9
VMi 11
VMi 14
VMi 17
Mains connection
400 V 3~ 50 Hz
Starting current
A
17
23
32
35
43
Operating current at
+35/+55 °C
A
3.28/
4.18
4.33/
5.52
5.04/
6.29
6.84/
8.17
7.45/
9.24
Supply cable size
(bivalent system in
brackets)
mm
2
5 x 2.5
(5 x 6)
5 x 2.5
(5 x 6)
5 x 2.5
(5 x 6)
5 x 2.5
(5 x 6)
5 x 2.5
(5 x 6)
Supplementary electric
immersion heater output
kW
6
Soft starter as standard
Yes
Load guard
Optional accessory
Compressor motor
protection circuit breaker
ratings
A
6
7
9
10
12
Fuses
Parallel
operation with
supplementary
heater
VSi 6 VSi 8
VSi
10
VSi
12
VSi
14
VMi 6 VMi 9
VMi
11
VMi
14
VMi
17
Disabled
3x10
3x16
3x10
3x16
Enabled
3x16
3x20
3x16
3x20
M8011 2204EN
59 (70)
Содержание VMi 6-17
Страница 1: ...M8011 2204EN 25 January 2022 Installation and operation manual VSi 6 14 VMi 6 17 ss Control...
Страница 2: ......
Страница 59: ...Dimensional drawings VSi 10VS14_2 VSI 1 ver 1 10VS14_2 VSI 2 ver 1 M8011 2204EN 57 70...
Страница 60: ...Dimensional drawings VMi 10VMI141_2 VMI 1 ver 1 10VMI141_2 VMI 2 ver 1 58 70 M8011 2204EN...
Страница 73: ......