If the heating circuit’s
flow temperature
measurement
is enabled, the flow water
temperature is displayed next to the circuit number.
● In the figure, flow water temperature is 32 °C.
If the heating circuit’s
room temperature
measurement
is enabled, the relevant room
temperature is displayed instead.
● In the figure, room temperature is 22 °C.
Increase or decrease heating
The
Home
view includes an icon for increasing or decreasing heating in the selected
circuit.
This icon will not be displayed, if the circuit has no room temperature measurement
available (or room temperature optimization has been disabled). A positive value will
increase room temperature, and a negative value will decrease the temperature.
As changes in room temperature are slow, you should change this setting by one or
two degrees at a time. Wait for one or two days for the change to become noticeable.
The increase or decrease heating setting changes the circuit’s heating curve by moving
each of the curve’s points up or down by the selected value. In practice, this has the
same effect as parallel displacement of the curve. If you change the curve manually,
the increase or decrease in heating will be reset.
Use cases
Too cold → Increase heating (+)
Too hot → Decrease heating (–)
Radiator heating, guideline values
Floor heating, guideline values
Room tempe1 °C → Increase by 6 (+6)
Room temperature −1 °C → Decrease by 6 (−6)
Room tempe1 °C → Increase by 3 (+3)
Room temperature −1 °C → Decrease by 3 (−3)
6 (31)
M8004 2123EN
Содержание EasyAce
Страница 1: ...M8004 2123EN 10 June 2021 Installation and operation manual EasyAce EasyAce User Manual...
Страница 2: ......
Страница 4: ...2 31 M8004 2123EN...
Страница 34: ...32 31 M8004 2123EN...
Страница 35: ......