![OilGear EPC 300 Series Скачать руководство пользователя страница 33](http://html2.mh-extra.com/html/oilgear/epc-300-series/epc-300-series_user-manual_3560280033.webp)
EPC
SERVO AMPLIFIER MODULE
Part Number L723888-3xx
ELECTRONIC
Telephone: (231) 929-1660
Oilgear
Fax:
(231) 929-7879
1424 International Dr
Issued May 31, 2018
Web Site:
www.oilgear.com
Traverse City, MI USA 4 9 6 8 6
Bulletin 836260F
33
4.3.2.5 Output Current Limit
The Module can be current limited to protect the valve or limit stroke. The current limit is
selected from program item 803 of the Pump Controller Form and is expressed as 0 to 100% of
the maximum current of the module (250mA).
Current is limited in each direction, so a Current Limit of 50% will limit the current to -50% to
+50% of the maximum.
4.3.2.6 Dither
The EPC provides for a dither signal that is superimposed on the final output to the current
driver. The dither is set from the Pump Controller Form (the dither option is only available for
EPC modules with software version of 1.05 or later).
The dither frequency is fixed at 200Hz. The amplitude of the dither signal is expressed in DAC
counts, with 0 equal to no dither and 255 equal to maximum dither (approximately 12.5% of
maximum controller current).
Table 11 below shows several examples of dither values in DAC counts converted into
percent (%) and current (mA) for EPC3. The maximum current for EPC3 is 250mA.
Dither (DAC count)
Dither (%)
Dither (mA)
0
0.0%
0.00mA
51
2.5%
6.26mA
102
5.0%
12.52mA
154
7.5%
18.75mA
208
10.0%
25.00mA
255
12.5%
31.25mA
Table 11: Dither Examples