![OHM ELECTRIC Cool Cabi OCA-S1300BCD-A200 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/ohm-electric/cool-cabi-oca-s1300bcd-a200/cool-cabi-oca-s1300bcd-a200_instruction-manual_727132042.webp)
18
The cooling circuit of COOLCABI has been filled with a required amount of refrigerant,
tested for leaks and subject to a trial run before delivery. Therefore, there is no need of
maintenance for the circuit. The durability of COOLCABI is generally 30,000 operating
hours, provided that its filter is kept clean. Depending on the environmental condition at
the site of use, check and clean the filter, if used, at least once a week. Clogging on filter
may lead to deterioration in cooling performance, or at worst, may cause shutdown of
the unit due to overloading on the compressor.
7-1 Filter cleaning and replacement
(Example: OCA-S1300BCD-A200)
Draw a filter from the guide on the left
side of the cooling unit and then
carry out cleaning or replacement.
◎
Replacement filter for external suction port
Part No.
COOLCABI models to fit
CF-S1(2 pcs./set)
OCA-S350BCD
、
OCA-S700BCD
CF-S8(2 pcs./set)
OCA-S1300BCD
CF-S2(2 pcs./set)
OCA-S2300BCD
7-2 Replacement of external fan
(Example: OCA-S1300BCD-A200)
In the event of a fan failure, go through the following steps to replace the fan.
(1)
Remove the suction port filter on external side and then remove
the four screws shown in the right to take
(2)
Pull out the fan cord, insulation rubber and the ground wire and remove
the fixing screws and nuts of the fan.
(3)
Attach a replacement fan to the fan mounting plate.
* Place the fan so as to inhale air from outside.
(4)
Fit the insulation rubber, fan cord and ground wire and then reattach
the fan mounting plate to the cooling unit.
*Pay attention not to tuck the fan cord under the plate.
◎
Replacement fan
Applicable COOLCABI models
Model
Internal fan
External fan
OCA-S350BCD-A200
FM-350BCDIN-200V
FM-350BCDOUT-200V
OCA-S700BCD-A200
FM-700BCDIN-200V
FM-700BCDOUT-200V
OCA-S1300BCD-A200
FM-1300BCDIN-200V FM-1300BCDOUT-200V
OCA-S2300BCD-A200
FM-2300BCDIN-200V FM-2300BCDOUT-200V
Suction port filter
(white)
Screw
(4 places)
Fan mounting
plate
Fan cord
Insulation rubber
Ground screw
Ground
wire
Fan fixing
screws
Nut
Содержание Cool Cabi OCA-S1300BCD-A200
Страница 1: ...OCA S350BCD A200 OCA S700BCD A200 OCA S1300BCD A200 OCA S2300BCD A200...
Страница 2: ...2 20 50 85 RH 70...
Страница 3: ...3 OCA S1300BCD A200 OCA S1300BCD A200 14 35 85 RH 3...
Страница 4: ...4 M6 2 200mm 30...
Страница 5: ...5 P 6 P 7 OCA S1300BCD A200 OCA S700BCD OCA S1300BCD OCA S2300BCD A200...
Страница 6: ...6 OCA S350BCD A200 OCA S700BCD A200 OCA S1300BCD A200 OCA S2300BCD A200...
Страница 7: ...7 OCA S350BCD A200 OCA S1300BCD A200 35 85 RH...
Страница 10: ...10 OCA S2300BCD A200 1 30mA...
Страница 11: ...11 30 ON OFF 1 6 ON OFF ON OFF P 12 35 Set Up Down 35 30 45 Set Up Down 3 30 Down Up Set ALARM Set Down Up RUN...
Страница 15: ...15 35 5 35 30 4 P 14 3 30 1 30 5 35 30 ON OFF ON OFF 35 30 ON OFF ON OFF...
Страница 16: ...16 7 3 5 5 35 30 ON OFF ON OFF 30 35 45 ON OFF ON OFF...
Страница 17: ...17 45 P 14 43 P 14 Set 3 P 14 Set 1 P 14 OFF...
Страница 19: ...19 OCA S1300BCD A200 P 18 OCA S1300BCD A200 35 85 RH OCA S350BCD OCA S700BCD OCA S1300BCD OCA S2300BCD...
Страница 20: ...20 OCA S2300BCD A200 50 45 P 11 P 4 P 18 19 P 19 OFF No 7 5kW 1 4 P11 5 4...
Страница 22: ...22 OCA S350BCD A200 OCA S700BCD A200 12 12 2 M8 13 4 M6 14 4 M6 14...
Страница 23: ...23 OCA S1300BCD A200 OCA S2300BCD A200 12 12 2 M8 13 4 M6 14 2 M8 13 6 M8 14...
Страница 24: ...24 1 13 64 19 10 4 431 1304 7000 21 TEL 053 522 5572 FAX 053 522 5573 8 2019 5...