Parameter setting register
☞
See page 4 to 43
Register No.
Description
Value
R W
DEC
HEX
56
x Setting temperature
3 to 45
℃
R W
57
x Differential df
3 to
℃
R W
58
x orced cooling operation time Cd
to 3 to 3 seconds
R W
59
x 3 High temperature alarm AL
35 to 5
℃
R W
6
x 4 Differential for High temp. alarm dA
to
℃
R W
6
x 5 Maintenance reminder I
to 99
R W
6
x 6 orced cooling operation setting at power input CS : O , : ON
R W
63
x 7 Restoration method from Overheat Pr
: Manual reset, : Auto reset
R W
64
x 8 Contact output setting for maintenance reminder o
: Not switches, : Switches
R W
65
x 9 Assignment of alarm output contact AS
to 3
☞
See page 47
R W
66 x A Choose how to switch alarm output contact Ao
,
☞
See page 47
R W
67 x B Setting of operation mode rM
: Continuous run : Energy save OP
: Energy save OP 3: Energy save OP3
R W
68 x C Setting of cooling OP time for Energy saving mode 3 t
7 to 6 minutes
R W
69 x D Shutdown time of ext. fan and compressor t
3 to minutes
R W
7 x E Setting of communication address Ad
to 99
R
7 x Communication speed br
: 48 bps
3: 384 bps
: 96 bps
4: 576 bps
: 9 bps
R
7
x Parity Pb
: No parity
: Odd parity
:
Even parity
R
73
x Display of software version Sn
Return fixed value
R
Note: When writing a value to non-writable data, a successful response is returned but writing is not done.
③
Time Alarm history register
Register No.
Description
Value
R W
DEC
HEX
769
x 3 Maintenance time
[ x ] to 99 [ x 6AC] hour
R
77
x 3 Cumulative operation time H High-order
[ x ] to 99999[ x 869 ]
hour
R
77
x 3 3 Cumulative operation time L Low-order
R
77
x 3 4 Cumulative compressor run time H High-order
[ x ] to 99999[ x 869 ]
hour
R
773
x 3 5 Cumulative compressor run time L Low-order
R
774
x 3 6 Cumulative external fan run time H High-order
[ x ] to 99999[ x 869 ]
hour
R
775
x 3 7 Cumulative external fan run time L Low-order
R
776
x 3 8 Cumulative internal fan run time H High-order
[ x ] to 99999[ x 869 ]
hour
R
777
x 3 9 Cumulative internal fan run time L Low-order
R
778 x 3 A
Alarm history latest : Control number*
5
, Alarm history
code*
6
Control number*
5
High-order : [ x ] to 99[ x63]
Alarm history code*
6
Low-order : [ x ] to 99[ x63]
R
779 x 3 B Alarm history latest : eneration time H High-order
[ x ] to 99999[ x 869 ]
hour
R
78 x 3 C Alarm history latest : eneration time L Low-order
R
78 x 3 D Alarm history : Control number*
5,
Alarm history code*
6
Control number*
5
High-order : [ x ] to 99[ x63]
Alarm history code*
6
Low-order : [ x ] to 99[ x63]
R
78 x 3 E Alarm history : eneration time H High-order
[ x ] to 99999[ x 869 ]
hour
R
783 x 3 Alarm history : eneration time L Low-order
R
・
・
・
835
x 343
Alarm history oldest : Control number*
5,
Alarm
history code*
6
Control number*
5
High-order : [ x ] to 99[ x63]
Alarm history code*
6
Low-order : [ x ] to
99[ x63]
R
836
x 344
Alarm history oldest : eneration time H High-
order
[ x ] to 99999[ x 869 ]
hour
R
837
x 345 Alarm history oldest : eneration time L Low-order
R
*5
Serial number allocated in order of alarm occurrence starting with and returning to after 99.
*6
Correspondent table between Alarm numbers and Alarm history codes
Alarm No.
E E3 E4 E5 E6 E7 E8 EC S S S3 S4 S5 SE
tE
Alarm history code
3
4
5
6
7
8
-
5
5
53
-
-
9
-
Note: The alarm numbers EC, S4, S5 and tE are not stored in alarm history when they occurred.
Содержание COOL CABI OCA-H1000BC-AW2
Страница 3: ...3 20 50 85 RH 0 60 85 RH R1234yf...
Страница 4: ...4 2 1...
Страница 6: ...6 8 9 COOLCABI...
Страница 7: ...7 8 2 2 9 COOLCABI COOLCABI COOLCABI...
Страница 10: ...10 500mm 500mm 35 85 RH OK COOLCABI COOLCABI NG NG COOLCABI L COOLCABI COOLCABI 500mm NG NG NG NG OK NG...
Страница 12: ...12 30 ON OFF 1 6 ON OFF ON OFF 13 No Up UP Down Down Set...
Страница 15: ...15 35 5 35 30 4 E 3 30 1 30 5 35 30 35 30 ON OFF ON OFF ON OFF ON OFF...
Страница 16: ...16 7 3 5 5 45 35 30 30 ON OFF ON OFF ON OFF ON OFF 35...
Страница 28: ...28 OCA H300BC AW2 OCA H600BC AW2 OCA H1000BC AW2 OCA H1600BC AW2 OCA H2200BC AW2 OCA H2900BC AW2...
Страница 29: ...29 OCA H300AC AW2 OCA H700AC AW2 OCA H1100AC AW2 OCA H1700AC AW2 OCA H2300AC AW2 OCA H3000AC AW2...
Страница 30: ...30 OCA H350BCD AW2 OCA H700BCD AW2 OCA H1300BCD AW2 OCA H2300BCD AW2 1...
Страница 58: ...58 Standard Roof mounting type OCA H3 AC AW OCA H7 AC AW OCA H AC AW OCA H 7 AC AW OCA H 3 AC AW OCA H3 AC AW...
Страница 60: ...60 20 50 85 RH 20 60 85 RH R1234yf LFL 25 OFN...
Страница 61: ...61 2 1...
Страница 62: ...62 12 5 N m 2 200mm 200mm COOLCABI 200mm COOLCABI 90 90 90 COOLCABI 200mm COOLCABI 200mm 90 90 90 90 COOLCABI...
Страница 63: ...63 30 65 66 COOLCABI...
Страница 64: ...64 65 2 2 66 COOLCABI COOLCABI COOLCABI...
Страница 67: ...67 2 L 500mm 500mm 35 85 RH OK COOLCABI COOLCABI NG NG COOLCABI L COOLCABI COOLCABI 500mm NG NG NG NG OK NG...
Страница 69: ...69 30 ON OFF 1 6 ON OFF ON OFF 70 Up UP Down Down Set...
Страница 72: ...72 35 5 35 30 4 E 3 30 1 30 5 35 30 35 30 ON OFF ON OFF ON OFF ON OFF...
Страница 73: ...73 t1 t2 7 3 5 5 45 35 30 30 ON OFF ON OFF ON OFF ON OFF 35...
Страница 85: ...85 OCA H300BC AW2 OCA H600BC AW2 OCA H1000BC AW2 OCA H1600BC AW2 OCA H2200BC AW2 OCA H2900BC AW2...
Страница 86: ...86 OCA H300AC AW2 OCA H700AC AW2 OCA H1100AC AW2 OCA H1700AC AW2 OCA H2300AC AW2 OCA H3000AC AW2...
Страница 87: ...87 OCA H350BCD AW2 OCA H700BCD AW2 OCA H1300BCD AW2 OCA H2300BCD AW2 1...