28     255548 Rev.1

9 Technical data

9.1 Operating limits

−    Inlet pressure
−    Compression pressure
−    Pressure diff erence
−    Medium to be pumped
−    Operating liquid
−    Speed
−    Switching frequency

SM30B

Pressure

PSI

Operating Liquid (water)

Min. Inlet 
Pressure

19

Temperature

(

o

F)

Temperature

(

o

F)

Max.

176

Dry

392

Min

50

Saturated

212

Speed

RPM

Max

3500

Tab. 12 Operating limits SM30B

SM55, 75, 100, 200, 250B

Pressure

PSI

Operating Liquid (water)

Min. Inlet 
Pressure

19

Temperature

(

o

F)

Temperature

(

o

F)

Max.

176

Dry

392

Min

50

Saturated

212

Speed

RPM

Max

3500

Tab. 13 Operating limits SM55/75/100/200/250B

9.1.1 Media to be pumped

• 

Dry and wet gases which are not explosive,  
infl ammable, aggressive or toxic

• 

Air or air-steam mixtures

−  which are free of solids

−  which contain small amounts of light particulate 

matters

9.1.2 Switching frequency

Th

  e max. switching frequency of 20 switching cycles per 

hour should not be exceeded.

9.2 General technical data

Th

  e following data refer to standard values. For deviating 

data, please consult the manufacturer.

9.2.1 Weight

Type

Flange version 

Weight (lb)

Motor Size

SM30B

-

90

SM55B

148

100L

SM75B

183

112M

SM100B

245

132S/M

SM200B

360

160M

SM250B

342

160L

Tab. 17 Pump weights

9.2.2 Sound Level

Type

1m measured surface sound 
pressure level
L [db(A)]*        60 Hz

SM30B

72

SM55B

68

SM75B

68

SM100B

68

SM200B

73

SM250B

75

* Measured surface sound pressure level in acc. with DIN 
EN ISO 3744, at 1 m distance with average throttling (80 
mbar abs.) and connected pipes, tolerance ± 3 dB (A)

Tab. 18 Sound pressure level

9.2.3 Drive Power

Th

  e following data apply to operating liquids with a 

kinematic viscosity of ν ≤ 4 mm

2

/sec.

For operating liquids featuring a higher kinematic viscosity, 
the drive power has to be adjusted.

Type

Rated motor 

power [kw]

Rated motor 
speed [min

1

]

Direction 

of 

rotation 

as seen 

from the 

drive

Motor 

size

50 Hz 60 Hz 50 Hz 60 Hz

SM30B

3.0

4.0

2850

3450

clockwise

90

SM55B

3.0

4.6

1450

1750

clockwise

100L

SM75B

4.0

6.2

1450

1750

clockwise

112M

SM100B

5.5

-

1450

-

clockwise

132S

8.2

1750

132M

SM200B

7.5

13.2

1450

1750

clockwise

132M

160M

SM250B

11.0

18.0

1450

1750

clockwise

160M

160L

Tab. 19 Drive power

Содержание SM30B

Страница 1: ...ng Vacuum Pumps It is imperative to read the operating instructions prior to commissioning This document as well as all documents included in the appendix is not subject to any update service Subject...

Страница 2: ...4 5 2 2 Fixing aggregate 15 5 3 Set up without foundation 15 5 4 Set up on level surface frame 15 5 5 Planning pipe system 15 5 5 1 Dimensioning supports and connections 15 5 5 2 Specifying nominal di...

Страница 3: ...s for heat dissipation 30 9 2 10 Tightening torques 30 9 3 Conical pipe fittings 31 9 4 Permissible forces acting on pump nozzles 31 9 5 Preserving agents 31 9 5 1 Preservation filling volumes 31 9 6...

Страница 4: ...to third parties requires written approval of the manufacturer This also applies to the duplication or transfer of excerpts of these operating instructions and to the transfer of these operating inst...

Страница 5: ...ns and regulations related to the system Qualified staff assembler Read observe and adhere to these operating instructions and all applicable documents particularly the safety precautions and warnings...

Страница 6: ...uries or death by electric shock Instruction for action 1 2 Multi step instruction for action Pre requisite Cross reference Information note Tab 4 Symbols and meaning 1 4 Terminology Term Meaning Pump...

Страница 7: ...gainst overload When delivering solid laden liquids observe the solid content limit values General technical data page 28 Do not combine multiple limit values Operating limits page 28 Prevent sudden p...

Страница 8: ...l parts or parts approved by the manufacturer only All warranty and damage claims will expire in case of nonobservance of these operating instructions 2 3 3 Obligations of the staff Notes attached to...

Страница 9: ...55 55 1 2 3 1 Series 2 Size 3 Material design code Tab 6 Pump type code example 3 2 General description The pumps of the SM series are horizontal single stage liquid ring vacuum pumps with radial inle...

Страница 10: ...rinks during each rotation 1 Suction opening 2 Pressure opening 3 Liquid ring Fig 4 Functional principle of liquid ring vacuum pumps The arrangement of suction and pressure openings in the inter casin...

Страница 11: ...e following figures Do not stand under suspended loads Fig 5 Attaching lifting gear to the aggregate Lift the aggregate accordingly 4 2 Storage Pumps aggregates treated by the factory have been provid...

Страница 12: ...ss water connection by means of blank flanges screw plugs Fill in preserving agent into the open inlet nozzle Observe the filling volumes Filling volumes preservation page 31 Plug the inlet nozzle wit...

Страница 13: ...on pressure and operating liquid connection UB using transport or sealing covers Plug all drainage bores Ue with screw plugs 4 4 Removing preserving agent Only required for aggregates treated with pre...

Страница 14: ...dead weight of the aggregate and all operating forces adequate aggregate stability with concrete foundation standard concrete of strength class B 25 5 1 5 Removing preserving agent If the aggregate is...

Страница 15: ...ing the hexagon nut 2 Tighten the hexagon nut 1 Tightening torques page 30 Use the integrated spirit level to check whether the aggregate is level end to end and side to side with a maximum allowable...

Страница 16: ...t the motor side 5 6 Connecting pipes 5 6 1 Providing for clean piping Risk of material damage caused by aggregate contamination Make sure the inside of the aggregate is kept free of contamination 1 C...

Страница 17: ...eas ATEX additional instructions 6 1 Preparations for commissioning 6 1 1 Identifying pump type Identify the pump type Nameplate page 9 Pump types vary e g with regard to material suction capacity typ...

Страница 18: ...le temperature of the medium to be pumped 1 Open the pressure side fitting 2 Ventilation port if available open the fitting 3 Switch on the motor 4 Operating liquid open the fitting R I SK OF E L E C...

Страница 19: ...the permissible operating liquid temperature Operating limits page 28 Fig 13 Closed circulation cooling Observe the permissible operating liquid temperature Operating limits page 28 Pos Meaning S Suc...

Страница 20: ...by aggregate Stand by aggregate filled Operate the stand by aggregate at least once per week 7 Maintenance and servicing For aggregates in potentially explosive areas ATEX additional instructions A qu...

Страница 21: ...ainst corrosion and deposits Within this context certain water quality standards must be met Operating liquid page 29 When using operating liquids other than water please contact the manufacturer DA N...

Страница 22: ...mechanical seal 047 off the impeller hub 230 Push the stationary unit of the mechanical seal 047 out of the shaft sealing casing 441 5 Disassembly of valve flap 746 Loosen the hexagon head screw 901 1...

Страница 23: ...ring stack 950 individual discs alternately strung together SM30B 8x individual discs onto the long thread side of the impeller screw 906 and lubricate with grease Molykote Screw the impeller screw 90...

Страница 24: ...to the long thread side of the impeller screw 906 and coat with grease Molykote Screw the impeller screw 906 with the disc spring stack 950 into the motor shaft Apply a thin layer of grease Molykote t...

Страница 25: ...outlet nozzle opposite the motor feet Force the pump casing 101 into the shaft sealing casing 441 SM55 75B only Fasten the pump casing 101 to the shaft sealing casing 441 using hexagon head screws 90...

Страница 26: ...ect Cause Solution Motor does not start Motor One phase of the power supply is interrupted Check the power supply check the motor Two phases of the power supply are interrupted Check the power supply...

Страница 27: ...the pump clean it Internal components are subject to wear Replace the affected components Worn out control valve Replace the control valve Worn out shaft sealing Replace the shaft sealing Amount of d...

Страница 28: ...ard values For deviating data please consult the manufacturer 9 2 1 Weight Type Flange version Weight lb Motor Size SM30B 90 SM55B 148 100L SM75B 183 112M SM100B 245 132S M SM200B 360 160M SM250B 342...

Страница 29: ...nce e g www schweitzer chemie de to provide adequate corrosion protection 9 2 4 2 Other operating liquids When using operating liquids other than water please contact the manufacturer C AU T ION C AU...

Страница 30: ...N GJL 250 CuZn Size Property class Tightening torque Nm M 6 8 8 8 5 M 8 8 8 12 M 10 8 8 25 M 12 8 8 40 M 16 8 8 90 Tab 26 Tightening torques for screws in cast iron casings 9 2 10 3 Stainless steel sc...

Страница 31: ...DN 50 140 430 DN 65 20 550 Tab 31 Permissible forces acting on pump nozzles 9 5 Preserving agents Rivolta preserving agent recommended or comparable products Type of storage Period of storage months...

Страница 32: ...formity 10 3 Dimensional drawing SM30B Fig 16 Dimensional drawing SM30B MODEL HZ MOTOR SIZE h3 u1 u2 q w z z2 A AB B BB C H HA HD SM30B 50 60 90 6 7 2 4 3 2 9 6 9 16 1 14 8 5 5 6 7 4 9 6 1 2 2 3 5 4 9...

Страница 33: ...eal 101 Pump casing 137 Inter casing 230 Impeller 411 1 Sealing ring 441 Shaft sealing casing 550 1 550 3 Washer 561 1 Grooved pin 598 Steel sheet 746 Valve flap 800 Motor 901 1 Hexagon head screw 902...

Страница 34: ...4 0 5 10 12 SM75B 50 60 112M 11 3 12 9 2 5 11 7 1 8 9 21 7 18 7 7 5 8 9 5 5 7 0 2 8 4 4 6 11 12 6 SM100B 50 60 132S 132M 12 3 12 9 2 4 11 6 7 9 11 4 27 1 23 9 8 5 10 1 5 5 7 0 8 6 4 3 5 2 7 12 6 16 8...

Страница 35: ...eal 101 Pump casing 137 Inter casing 230 Impeller 411 1 Sealing ring 412 O ring 441 Shaft sealing casing 550 1 Washer 561 1 Grooved pin 598 Steel sheet 746 Valve flap 800 Motor 900 Screw 901 1 901 3 H...

Страница 36: ...Pump casing 137 Inter casing 230 Impeller 411 1 Sealing ring 412 O ring 441 Shaft sealing casing 550 1 Washer 561 1 Grooved pin 598 Steel sheet 746 Valve flap 800 Motor 901 2 Hexagon head screw 903 1...

Страница 37: ...12 2 28 3 28 3 10 12 6 8 3 10 2 4 1 6 3 9 16 2 6 20 2 SM250B 50 160M 14 2 12 8 32 5 28 9 10 12 6 8 3 10 2 4 1 6 3 9 16 2 6 20 2 60 160L 14 2 12 8 32 5 28 9 10 12 6 10 12 4 1 6 3 9 16 2 6 20 2 Tab 44...

Страница 38: ...230 Impeller 400 Flat gasket 411 Sealing ring 412 O ring 441 Shaft sealing casing 550 1 Washer 561 1 Grooved pin 598 Steel sheet 723 Threaded flange 746 Valve flap 800 Motor 900 Screw 901 3 Hexagon he...

Страница 39: ...ial safety precautions The following safety precautions must be observed when handling the pump aggregate __________________________________________________________________________________________ ___...

Страница 40: ...ical Corporation This document contains information that is proprietary and confidential to Ohio Medical Corporation Use of this information is under license from Ohio Medical Corporation Any use othe...

Отзывы: