Compliance 

 

This product conforms to the EMC Directive 2004/108/EC and the Low Voltage 

Directive 2006/95/EC.  The Declaration of Conformity is available online at 

europe.ohaus.com/europe/en/home/support/compliance.aspx. 

 

In conformance with the European Directive 2002/96/EC on Waste Electrical 

and Electronic Equipment (WEEE) this device may not be disposed of in 

domestic waste. This also applies to countries outside the EU, per their specific 

requirements. Please dispose of this product in accordance with local 

regulations at the collecting point specified for electrical and electronic 

equipment. If you have any questions, please contact the responsible authority 

or the distributor from which you purchased this device. Should this device be 

passed on to other parties (for private or professional use), the content of this 

regulation must also be related. Disposal instructions in Europe are available 

online at europe.ohaus.com/europe/en/home/support/weee.aspx. Thank you for 

your contribution to environmental protection. 

 

FCC Note:

 This equipment has been tested and found to comply with the limits for a Class 

A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference when the equipment is operated in a 

commercial environment. This equipment generates, uses, and can radiate radio frequency 

energy and, if not installed and used in accordance with the instruction manual, may cause 

harmful interference to radio communications. Operation of this equipment in a residential 

area is likely to cause harmful interference in which case the user will be required to correct 

the interference at his own expense.  

 

ISO 9001 Registration 

In 1994, OHAUS Corporation, USA, was awarded a certificate of registration to ISO 9001 by 

Bureau Veritus Quality International (BVQI), confirming that the OHAUS quality 

management system is compliant with the ISO 9001 standards requirements. On June 21, 

2012, OHAUS Corporation, USA, was re-registered to the ISO 9001:2008 standard. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание STARTER 2100

Страница 1: ...STARTER 2100 Bench pH Meter Instruction Manual...

Страница 2: ...STARTER 2100 Bench pH Meter EN 2...

Страница 3: ...7 3 SETUP 8 3 1 Set MTC temperature 8 4 STARTER 2100 OPERATION 9 4 1 Calibration 9 4 1 1 Buffer group 9 4 1 2 Performing 1 point calibration 10 4 1 3 Performing 2 point calibration 11 4 2 Sample measu...

Страница 4: ...STARTER 2100 Bench pH Meter EN 2...

Страница 5: ...ode performance Recall of last calibration data Quick Guide attached under the meter to assist with operation 1 1 Definition of Signal Warnings and Symbols Safety notes are marked with signal words an...

Страница 6: ...that the power cord does not pose a potential obstacle or tripping hazard Use the equipment only in dry locations Dry off any liquid spills immediately The instrument is not watertight When using chem...

Страница 7: ...t 35 60 mV Electrode condition is not good or needs cleaning 2 Measurement icon measurement or calibration is running disappear means the reading is locked no matter measurement 3 Calibration icon 1 p...

Страница 8: ...Confirm temp setting Start calibration Review the latest calibration data slope offset Meter turn on Exit return to measurement screen Meter turn off Entered temperature setup mode Increase temp value...

Страница 9: ...3965 ST210 2 in 1 plastic refillable pH Electrode 83033966 ST320 3 in 1 plastic gel pH Electrode no need to refill 83033967 ST230 2 in 1 glass muddy sample pH Electrode 83033968 STTEMP30 Temperature E...

Страница 10: ...ht sight of the STARTER 2100 meter Remove the rubber hole cover from the meter Insert the metal stick into the hole and screw to fasten it Install the upper electrode arm upon the metal stick from abo...

Страница 11: ...connect the pH electrode with the pH socket BNC For temperature electrode STTEMP30 connect with Temp Socket Cinch For pH electrode ST310 connect both the BNC and Cinch socket The banana REF socket is...

Страница 12: ...used the meter automatically switches to Manual Temperature Compensation MTC mode and MTC appears on the screen MTC can be set as follows Press button and the MTC temperature value appears on the disp...

Страница 13: ...into the sample or buffer solution the user should stir several seconds then wait 30 to 60 seconds for the signal to stabilize and then press the proper button to operate calibration or measurement WA...

Страница 14: ...0 60 seconds Press button Cal 1 displays on the top right of the screen and is blinking The measurement icon appears on the top of the screen is blinking during calibration When the reading is stable...

Страница 15: ...ght of the screen and is blinking appears and is blinking during calibration When reading is stable normally the reading does not change in 5s press button to lock the reading and finish 2 point calib...

Страница 16: ...s button 4 2 2 mV measurement Press button to switch between pH measurement mode and mV measurement mode Follow the same procedure as for pH measurement to perform a mV measurement 4 3 Temperature mea...

Страница 17: ...require any routine maintenance To clean use a damp cloth The housing is made of acrylonitrile butadiene styrene ABS This material is susceptible to damage by some organic solvents such as toluene xy...

Страница 18: ...reen continue to press the other keys until all the icons have disappeared When the self diagnosis has been completed successfully appears means pass If self diagnosis fails error message Err appears...

Страница 19: ...ution degree 2 Operability is assured at ambient temperatures between 5 C to 40 C Model ST2100 Measuring range 0 00 14 00 pH 1999 1999 mV 0 C 100 C Resolution 0 01 pH 1 mV 0 1 C Error limits 0 01 pH 1...

Страница 20: ...able online at europe ohaus com europe en home support weee aspx Thank you for your contribution to environmental protection FCC Note This equipment has been tested and found to comply with the limits...

Страница 21: ...4 06 6 97 8 99 10 10 Buffer group JJG119 Temp C pH1 68 pH4 00 pH6 86 pH9 18 pH12 46 5 1 67 4 00 6 95 9 39 13 21 10 1 67 4 00 6 92 9 33 13 01 15 1 67 4 00 6 90 9 28 12 82 20 1 68 4 00 6 88 9 23 12 64 2...

Страница 22: ...t has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other...

Страница 23: ...STARTER 2100 PT 15...

Страница 24: ...3 944 7177 With offices worldwide Con oficinas en todo el mundo Avec des bureaux dans le monde entier Com escrit rios no mundo inteiro www ohaus com PN 30031622 D Ohaus Corporation 2014 all rights res...

Отзывы: