OHAUS STARTER 2100 Скачать руководство пользователя страница 14

EN-10                                                        STARTER 2100 Bench pH Meters                                                                                                                                                                               

 

 
 

 

 

 

 
 

 

 
 
 

 
 

4.1.2  Performing 1-point calibration 

Calibration:

  pH  electrodes  need  to  be  calibrated  with  pH  standard  buffer  solutions  before  a 

proper pH measurement can be made. 

Calibration

 is to display the correct 

pH

 value when the 

meter receives the 

mV

 value signal from the pH electrode.  

Slope

: the linear coefficient between mV and pH according to theoretical value (e.g.  -

59.16mV/pH @ 25 °C which means 100% slope); 

Offset

: the mV value when pH value is 7.00. (Theoretical value is 0 mV); 

 

 

Begin by ensuring the meter is plugged in, the electrode is properly attached and the meter is 

powered on by pressing

 

 

Place the pH electrode in the prepared buffer solution, stir for approximately 5 seconds and 
wait for an additional 30-60 seconds. 

 

Press button-

, “

Cal 1

” displays on the top right of the screen and is blinking. The 

measurement icon   appears on the top of the screen,    is blinking during calibration.  

 

When  the  reading  is  stable  (normally  the  reading  does  not  change  in  5s),  press  button-

 to  lock  the  reading  and  finish  1 point  calibration. The  buffer  value  (e.g.  pH  7.00) 

with  the  temperature  is  displayed  on  the  screen;  the  meter  can  recognize  the  buffer 

automatically (auto buffer recognition). 

 
The 1-point calibration is finished; now we have 3 options:  

  Press button-

 to store the 1-point calibration data and exit, the 

offset

 and the 

slope

 

are shown on the display for 3 seconds then returns to the measurement screen. 

5 °C 

1.67 

4.01 

7.09 

10.25 

10 °C 

1.67 

4.00 

7.06 

10.18 

15 °C 

1.67 

4.00 

7.04 

10.12 

20 °C 

1.68 

4.00 

7.02 

10.06 

25 °C 

1.68 

4.01 

7.00 

10.01 

30 °C 

1.68 

4.01 

6.99 

9.97 

35 °C 

1.69 

4.02 

6.98 

9.93 

40 °C 

1.69 

4.03 

6.97 

9.89 

45 °C 

1.70 

4.05 

6.97 

9.86 

50 °C 

1.71 

4.06 

6.96 

9.83 

Содержание STARTER 2100

Страница 1: ...STARTER 2100 Bench pH Meter Instruction Manual...

Страница 2: ...STARTER 2100 Bench pH Meter EN 2...

Страница 3: ...7 3 SETUP 8 3 1 Set MTC temperature 8 4 STARTER 2100 OPERATION 9 4 1 Calibration 9 4 1 1 Buffer group 9 4 1 2 Performing 1 point calibration 10 4 1 3 Performing 2 point calibration 11 4 2 Sample measu...

Страница 4: ...STARTER 2100 Bench pH Meter EN 2...

Страница 5: ...ode performance Recall of last calibration data Quick Guide attached under the meter to assist with operation 1 1 Definition of Signal Warnings and Symbols Safety notes are marked with signal words an...

Страница 6: ...that the power cord does not pose a potential obstacle or tripping hazard Use the equipment only in dry locations Dry off any liquid spills immediately The instrument is not watertight When using chem...

Страница 7: ...t 35 60 mV Electrode condition is not good or needs cleaning 2 Measurement icon measurement or calibration is running disappear means the reading is locked no matter measurement 3 Calibration icon 1 p...

Страница 8: ...Confirm temp setting Start calibration Review the latest calibration data slope offset Meter turn on Exit return to measurement screen Meter turn off Entered temperature setup mode Increase temp value...

Страница 9: ...3965 ST210 2 in 1 plastic refillable pH Electrode 83033966 ST320 3 in 1 plastic gel pH Electrode no need to refill 83033967 ST230 2 in 1 glass muddy sample pH Electrode 83033968 STTEMP30 Temperature E...

Страница 10: ...ht sight of the STARTER 2100 meter Remove the rubber hole cover from the meter Insert the metal stick into the hole and screw to fasten it Install the upper electrode arm upon the metal stick from abo...

Страница 11: ...connect the pH electrode with the pH socket BNC For temperature electrode STTEMP30 connect with Temp Socket Cinch For pH electrode ST310 connect both the BNC and Cinch socket The banana REF socket is...

Страница 12: ...used the meter automatically switches to Manual Temperature Compensation MTC mode and MTC appears on the screen MTC can be set as follows Press button and the MTC temperature value appears on the disp...

Страница 13: ...into the sample or buffer solution the user should stir several seconds then wait 30 to 60 seconds for the signal to stabilize and then press the proper button to operate calibration or measurement WA...

Страница 14: ...0 60 seconds Press button Cal 1 displays on the top right of the screen and is blinking The measurement icon appears on the top of the screen is blinking during calibration When the reading is stable...

Страница 15: ...ght of the screen and is blinking appears and is blinking during calibration When reading is stable normally the reading does not change in 5s press button to lock the reading and finish 2 point calib...

Страница 16: ...s button 4 2 2 mV measurement Press button to switch between pH measurement mode and mV measurement mode Follow the same procedure as for pH measurement to perform a mV measurement 4 3 Temperature mea...

Страница 17: ...require any routine maintenance To clean use a damp cloth The housing is made of acrylonitrile butadiene styrene ABS This material is susceptible to damage by some organic solvents such as toluene xy...

Страница 18: ...reen continue to press the other keys until all the icons have disappeared When the self diagnosis has been completed successfully appears means pass If self diagnosis fails error message Err appears...

Страница 19: ...ution degree 2 Operability is assured at ambient temperatures between 5 C to 40 C Model ST2100 Measuring range 0 00 14 00 pH 1999 1999 mV 0 C 100 C Resolution 0 01 pH 1 mV 0 1 C Error limits 0 01 pH 1...

Страница 20: ...able online at europe ohaus com europe en home support weee aspx Thank you for your contribution to environmental protection FCC Note This equipment has been tested and found to comply with the limits...

Страница 21: ...4 06 6 97 8 99 10 10 Buffer group JJG119 Temp C pH1 68 pH4 00 pH6 86 pH9 18 pH12 46 5 1 67 4 00 6 95 9 39 13 21 10 1 67 4 00 6 92 9 33 13 01 15 1 67 4 00 6 90 9 28 12 82 20 1 68 4 00 6 88 9 23 12 64 2...

Страница 22: ...t has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other...

Страница 23: ...STARTER 2100 PT 15...

Страница 24: ...3 944 7177 With offices worldwide Con oficinas en todo el mundo Avec des bureaux dans le monde entier Com escrit rios no mundo inteiro www ohaus com PN 30031622 D Ohaus Corporation 2014 all rights res...

Отзывы: