background image

Ranger  4000 Count Series                                                                                               EN 29 

Command  Function 

 
MT-SICS Commands

 

 

Command 

Function 

LEVEL 0  @ 

Reset the scale 

I0 

Inquiry of all available SICS commands 

I1 

Inquiry of SICS level and SICS versions 

I2 

Inquiry of scale data 

I3  

Inquiry of scale software version 

I4 

Inquiry of serial number 

Send stable weight value 

SI 

Send weight value immediately  

SIR 

Send weight value repeatedly 

Zero the scale 

ZI 

Zero immediately 

LEVEL 1  D 

Write text into display 

DW 

Weight display 

SR 

Send and repeat stable weight value 

Tare 

TA 

Tare value 

TAC 

Clear tare 

TI 

Tare immediately  

 
7.3.2 Connections for RS232 

The 9-
The pin connections are as follows: 
Active pins: PIN 2 = TXD, PIN 3 = RXD, PIN 5 = Ground 
 

 

 

Figure 7-2. RS232 Pins 

 
 

7.4 Printouts 

The  following sample print  outs  are generated by the 

Print

 

print  command.  The  content  of  the  printout  is  defined  in  the  Print  Content  menu  item.  A 
maximum of 24 characters can be printed on each line. 
 

 

 

 

 

Description 

Comment 

 

Part Number line

 

If Printx   Content   P/N is ON

 

Result line 

If Printx   Content   Result is ON 

Gross value line 

If Printx   Content   Gross is ON and a tare value is entered 

Net value line 

If Printx   Content   Net is ON and a tare value is entered 

Tare value line 

If Printx   Content   Tare is ON and a tare value is entered 

Information line 

If Printx   Content   Info is ON 

Accumulation line 

If Printx 

Content 

Accu is All

Accumulation line 

If Printx   Content   Accu is All 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание R41ME15

Страница 1: ...Range 4000 Count Series Instruction Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...Alternating Current 1 2 Safety Precautions Please follow these safety precautions Verify that the AC input voltage printed on the data label matches the local AC power supply Only connect the power c...

Страница 3: ...scale on a firm steady surface Avoid locations with excessive air current vibrations heat sources or rapid temperature changes Allow sufficient space around the scale 2 4 Leveling the Equipment The Ra...

Страница 4: ...e battery charge level The scale will automatically turn off when the batteries are fully discharged For maximum operating time the battery should be charged at room temperature TABLE 2 1 Symbol Charg...

Страница 5: ...ghing unit Switch between Check Weigh Check Count and Off Menu Enter user menu View the Audit Trail event counters extended press Menu Function Short Press Yes Accept the current menu or setting No Ad...

Страница 6: ...3 2 LCD Symbols Item Description Item Description 1 NET symbol 10 Low Sample Weight Symbol 2 Center of Zero symbol 11 Auto Optimization Symbol 3 Negative symbol 12 Dynamic symbol not used 4 Stable wei...

Страница 7: ...d hold the On Zero Off button until OFF is displayed 3 3 Counting Ranger Count 4000 has three display areas Weight Piece Weight and Count information are displayed in these areas respectively 3 3 1 Pr...

Страница 8: ...size value only integer 5 Press the Sample key will be displayed in both the piece window and the count window 6 The established APW and count will be displayed Entering a known APW 1 Press the APW ke...

Страница 9: ...eight is under the target weight range the yellow LED will light If the sample is within the target weight range the green LED will light If the sample is over the target weight range the red LED will...

Страница 10: ...aximum 30 records from 0 to 29 Retrieving a record 1 Enter the ID number using the keypad and press the ID key and are displayed in the weight and piece weight windows respectively 2 ID number is disp...

Страница 11: ...ad and press the ID key and are displayed in the weight and piece weight windows respectively 2 Press the C key is displayed in the weight window Press the Yes key to delete the data www GlobalTestSup...

Страница 12: ...l models When LEGAL FOR TRADE is set to ON LFT Switch in locked position the menu settings are affected as follows Calibration C A L menu is not accessible Dual Scale Capacity 2 Graduation 2 and Units...

Страница 13: ...erforming the calibration be sure to have the appropriate calibration weights as listed in table 4 1 Ensure that the LFT switch calibration lock is set to unlocked position See figure 5 1 Or adjust th...

Страница 14: ...ing the default Refer to table 4 2 to determine the GEO factor that corresponds to your location End Cal Advance to the next menu or return to the top of the current menu 4 3 Setup Menu Enter this men...

Страница 15: ...unces Zero Range Set the percentage of scale capacity that may be zeroed 2 zero up to 2 percent of capacity 10 zero up to 10 percent of capacity Auto Opt Set the Automatic Optimization OFF disabled ON...

Страница 16: ...d Accumulation Set the accumulation functionality OFF accumulation disabled AUTO automatic accumulation MAN manual accumulation End Setup Advance to the next menu or return to the top of the current m...

Страница 17: ...ic shut off functionality OFF disabled 1 powers off after 1 minute of no activity 5 powers off after 5 minute of no activity 10 powers off after 10 minute of no activity End Readout Advance to the nex...

Страница 18: ...g occurs at the defined interval ACCEPT printing occurs continuously CONT printing occurs each time the display is within the Checkweigh accept range and stability criteria are met Content Define the...

Страница 19: ...ON the reference information is printed APW Set the status OFF disabled ON enabled Accu Set the status OFF disabled RESULT the Accumulation result is printed ALL all the Accumulation data is printed L...

Страница 20: ...7 setup contact Ohaus If the weighing value is a negative number set the target cell in TEXT format Otherwise Excel will not distinguish it as a negative number Please do not use this function during...

Страница 21: ...ernate command Define command character for the Print Tare and Zero commands Print Set the alternate command character for Print A to Z Tare Set the alternate command character for Tare A to Z Zero Se...

Страница 22: ...e status OFF COM menu is not locked ON COM menu is locked End Lock Advance to the next menu or return to the top of the current menu 4 9 End Menu current application mode 4 10 Additional Features To u...

Страница 23: ...EN 22 Ranger 4000 Count Series Figure 4 1 Setup for the Weigh Below Hook Weigh Below Hook Access www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 24: ...3 12 12 43 26 44 32 17 17 16 16 15 15 14 14 13 13 12 44 32 45 38 18 17 17 16 16 15 15 14 14 13 13 45 38 46 45 18 18 17 17 16 16 15 15 14 14 13 46 45 47 51 19 18 18 17 17 16 16 15 15 14 14 47 51 48 58...

Страница 25: ...h to Locked See figure 5 1 The Menu Lock switch limits changes to the Cal Setup Readout Unit and Print menus The switch in type approved models may set some scale settings as required by the approval...

Страница 26: ...0 Count Series EN 25 Figure 5 1 Sealing Unlocked Locked with Paper Seal Locked with Wire Seal Paper Seal Wire Seal Lock Switch www GlobalTestSupply com Find Quality Products Online at sales GlobalTest...

Страница 27: ...ot enabled Enter menu and enable unit Battery icon flashing Battery is empty Connect the scale to AC power and charge the battery Power On Error Weight reading exceeds Power On Zero limit Power On Err...

Страница 28: ...x 0 001 kg 30000 g x 1 g 60 lb x 0 002 lb 960 oz x 0 04 oz Maximum Displayed Resolution 1 30000 Minimum Recommended Sample Weight 2g 0 004lb 4g 0 01lb 10g 0 02lb 20g 0 04lb Minimum Recommended APW 0...

Страница 29: ...e or unstable P Print displayed weight stable or unstable CP Continuous Print SP Print on Stability xS xP Interval Print x Print Interval 1 3600 sec 0P turns auto print OFF Z Same as pressing Zero Key...

Страница 30: ...tive pins PIN 2 TXD PIN 3 RXD PIN 5 Ground Figure 7 2 RS232 Pins 7 4 Printouts The following sample print outs are generated by the Print print command The content of the printout is defined in the Pr...

Страница 31: ...haracters right justified at immediate left of most significant character if negative Unit Up to 5 characters left justified If the Unit in the Print Content menu was set to OFF the unit will be remov...

Страница 32: ...ations limit the validity period of the verification the user of the weighing instrument must strictly observe the re verification period and inform the respective weights and measures authorities FCC...

Страница 33: ...igned for safe removal of the batteries at end of life by a waste treatment facility Please dispose of this product in accordance with local regulations at the collecting point specified for electrica...

Страница 34: ...osed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than OHAUS In lieu of a properly returned wa...

Страница 35: ...ci in tutto il mondo 30037454 P N 30037454A 2015 OHAUS Corporation all rights reserved todos los derechos reservados tous droits r serv s Alle Rechte vorbehalten tutti i diritti riservati Printed in C...