iOS Devices, Mac OS and Windows PC
No user action is required on these platforms, however they may prompt a warning
dialogue/notification that there is no internet connectivity.
For other operating systems and specific device questions and answers,
please contact OHAir
support ohair.hydroxyl.info/support.
Wi-Fi Tips
Reconnecting to Existing Device
If you are having trouble reconnecting to your MySpace
TM
using an existing device,
please do the following:
Step 1: Search your MySpace
TM
(SSID) on Wi-Fi search list on your device
Step 2: Select your MySpace
TM
Step 3: Select ‘Forget Network’
Step 4: Follow the steps from the beginning in the previous section ‘Connecting Your
MySpace to Your Wi-Fi’
Your Notes
CAUTION: Unplug the device from the mains before removing cover.
Caring for your MySpace
TM
1 month
wash and air dry filter
CAUTION: Unplug the device from the mains before performing any cleaning
activities. Do not allow any excess water to enter the device or to come into contact
with the internal components. Do not use commercial surface cleaners.
The exterior surface of your MySpace
TM
can be cleaned with a soft cloth dampened
with a dilute solution of dishwashing detergent and water.
Removing Cover for Cleaning Air Filter and Replacing HGU
TM
2
1
3
2
It is recommended to remove and wash the air filter
monthly, more regularly if being used in a dusty area, by
removing the cover as below, extracting the air filter and
rinsing under the tap to remove large contaminants. Once
cleaned, it needs to be thoroughly air dried before
re-insertion.
Step 1 - Place the device on its back with power cord removed
Step 2 - Remove one screw
1
with PH2 Phillips screw driver
Step 3 - Push both tabs in together
2
to release cover
Step 4 - Lift cover upwards
3
and towards you to remove the cover
Step 5 - Re-assemble cover in reverse order
It is recommended to clean the internal chamber and the
optic assembly (HGU
TM
) quarterly, more regularly if being
used in a dusty area, to maintain its peak efficiency to
eliminate odours, bacteria, viruses and other volatile
organic compounds (VOCs) in the air and on surfaces. If the
HGU
TM
is in continuous operation, it is recommended to
replace the HGU
TM
annually with a new HGU
TM
purchasable
via the website. Every year when the HGU
TM
needs
replacement, it will display “driver expired” on the main
screen.
3 months
clean HGU
Page 5
Page 4
Internal Cooling Fan
The internal cooling fan is automatically controlled by the temperature of the drive
circuit. It may come on and off during operation of the device and can continue to run
for a couple of minutes after the main unit has been turned off.