future use.
⚫
Store all accessories with the unit in a dry, cool location.
REMOVING MINERAL BUILD-UP
⚫
Different water sources contain minerals and the sediment may cause mineral build-up in
the steamer and affect the free flow of steam.
⚫
NOTE: The best way to avoid mineral build-up is to use distilled or de-mineralised water.
If you are unable to do this it is recommended to use the mineral build-up removal
procedure.
⚫
Unplug the unit and allow to cool completely (at least 60 minutes). Remove all
accessories from the unit.
⚫
Remove the water tank cap and drain any remaining water from the water tank.
⚫
Slowly pour the mixture into the water tank.
⚫
Allow the unit to stand for 1-2 hours.
⚫
Drain the solution from the water tank.
⚫
If the mineral build-up still remains in the unit, repeat the above steps until all build-up is
removed.
⚫
Rinse the water tank with fresh water, drain and repeat until the vinegar odour is
eradicated.
⚫
Replace the water tank cap.
SPECIFICATION
⚫
Unit Weight (Bare): 0.568kg.
⚫
Water Tank Capacity: 240
ml.
⚫
Steam Output Time: 130 seconds.
⚫
Steam Duration: 14-18
minutes.
⚫
Voltage: 110-120V, 50/60Hz.
⚫
Wattage: 700W
TROUBLESHOOTING
Problem
Possible Reasons
Solution
Unit fails to heat. Unit is not plugged in.
Plug into mains power supply.
Switch is not activated.
Press the On/Off switch.
Unit heats up but
fails to steam.
Water tank is empty.
Refill the water tank according.
Mineral build-up in unit.
Follow the removing mineral
build-up guide.
Thermo-fuse breakdown.
Take to a certified service centre.