2.

 

Intended use 

 

Softcontrol  Smart  is  used  to  monitor  increased  hardness  concentrations  in  the  soft  water  of 
water  softening  systems  based  on  cation  exchangers.  It  offers  continuous,  safe  limit  value 
monitoring with an alarm when exceeded. At a fixed hardness limit of 10% based on the input 
water hardness, the device triggers an alarm. 
 

 

3.

 

Warranty 

 
The manufacturer guarantees the device for 2 years from delivery.  
The ion-selective sensor is an exception to this.  
The guarantee expires if:  

 

improper commissioning or improper operation or maintenance  

 

improper or unauthorized intervention in the device or its components  

 

improper analytical, mechanical or electrical impact of any kind  

 

damage or consequential damage caused by improper use or operation  

 

damage  or  consequential  damage  caused  by  faulty  or  improper  or  unauthorized  systems 
connected in the control and regulating circuit  

 

damage or consequential damage that can be traced back to poor quality sample liquids 

 

 

4.

 

Liability 

 

The manufacturer assumes no liability for upstream or downstream equipment and process / 
production processes of the user, their malfunctions, failures, damage or consequential dam-
age that are directly or indirectly connected to the monitoring or control circuit of the device 
or that have or  could  have an impact  on malfunctions or malfunctions in the manufacturer's 
devices 
The exclusion of liability is based on the fact that electrical impulses and currents, inorganic 
or  organic  precipitates,  sedimentation  of  corrosive  or  oxidizing  substances,  microbiological 
contamination, flocculation or putrefaction in the sample liquids occur only briefly and can be 
ignored by the user. 

Содержание Softcontrol Smart

Страница 1: ...Softcontrol Smart Instruction Manual Version 2 3...

Страница 2: ......

Страница 3: ...SIGNALING VIA POTENTIAL FREE CONTACT 13 9 3 2 CONNECTION EXTERNAL WATER METER 13 9 3 2 1 CONNECTION MECHANICAL WATER METER 13 9 3 2 2 CONNECTION ELECTRONICAL WATER METER TURBINE WITH HALL CONTACTS 13...

Страница 4: ...4...

Страница 5: ...mponents improper analytical mechanical or electrical impact of any kind damage or consequential damage caused by improper use or operation damage or consequential damage caused by faulty or improper...

Страница 6: ...ortance for a safe and hazard free operation of the device Attention Failure to comply with instructions marked in this way may result in damage to the device or the sensors Warning If notices marked...

Страница 7: ...w voltage The raw and soft water of the softening process to be monitored must basically meet the requirements of the applicable drinking water ordinance A constant sample pressure of a minimum of 1 t...

Страница 8: ...ly every 15 minutes in a flow measuring chamber in which a selective sensor for calcium and magnesium ions is inserted pres sure proof Alternatively the measuring cycle can be controlled by pulses fro...

Страница 9: ...ration Hard water alarm brine intrusion If the water hardness is detected in the soft water the visual alarm is triggered immediately and the external hard water alarm is triggered after a delay The d...

Страница 10: ...cated by an arrow on the filter housing The fine filters are preferably installed directly at the sam pling points for raw and soft water in order to also protect the sample hoses from clogging 2 Inse...

Страница 11: ...raw water optional connection water meter valve raw water measurement chamber power supply 240V 50 Hz V softener filter filter raw water sensor cable drain pressure free 1 1 2 3 5 6 4 sensor soft wate...

Страница 12: ...installation Optionally a water meter or an external signal output can be connected using the supplied 5 pin plug 1 2 3 4 N ot e E ac h te r m in al is m ar k e d w it h a n 5 S of t w at er Note The...

Страница 13: ...d to hide excess hardness lev els due to so called hardness it is recommended not to carry out the monitoring according to fixed time cycles but continuously during the entire soft water withdrawal To...

Страница 14: ...e time LED OK measurement lights up passive operation mode no increased water hardness recog nized good soft water quality LED OK measurement is flashing aktive operational mode measurement or calibra...

Страница 15: ...mly seated on the sensor and steamed up inside A comparison of the number on the sensor with the number given on the packaging and on the delivery note is recommended The sensor should be stored in th...

Страница 16: ...ng chamber in which the sensor is located and at the same time pull the used sensor straight out of the flow measuring chamber when changing sensors 4 Take the new sensor out of the folding box and pu...

Страница 17: ...nsor depending on its intensity and duration Strong deep black discolorations on the metal elec trodes indicate a high level of chlorine exposure The sensor can indicate that the limit value has been...

Страница 18: ...ensor not plugged in correctly or electrical plug connection defective Check plug connection or connection cable for continuity 3 Brine alarm high concentration of brine in the soft wa ter conductivit...

Страница 19: ...nsor protection cap filled with approx 1 ml of raw water carefully placed on the hardness sensor The sensor should be stored in a cool 10 15 C and dark place 14 Dismantling For dismantling the measuri...

Страница 20: ...or connection of water meter and external signal output 4 m flexible pressure proof PA line 4 mm OD 2 mm ID sampling hose 1 m flexible pressure proof PA line 8 mm OD 6 mm ID drainage hose 2 pieces scr...

Страница 21: ...x 4 watts Raw Soft water connection branch with connection option for PA hose OD 4 mm ID 2 mm particle condition 0 1 mm Raw Soft water pressure minimum 1 bar maximum 7 bars pressure difference as low...

Страница 22: ......

Страница 23: ...ezogen For verification in accordance with Low Voltage Directive 2014 35 EU the following standards were applied EN 61010 1 2010 Zum Nachweis entsprechend EMV Richtlinie 2014 30 EG wurden folgende Nor...

Страница 24: ...OFS Online Fluid Sensoric GmbH Heidelbergweg 9 07580 Ronneburg Germany Manual Softcontrol Smart Version 2 3 Issue 11 2020 Subject to technical changes...

Отзывы: