The MudCheckerApp is a conventional Windows

®

-based software application 

based on the Microsoft .NET Core framework. The minimum hardware and 

software requirements are:

•  Minimum 1 GHz processor

•  Minimum 8GB RAM

•  Minimum Windows 7 (x64) Operating System

•  Microsoft Office (minimum version 2020)

•  1 USB port – minimum USB 2.0

•  Microsoft .NET Desktop Runtime (x64 Architecture, Version 6.0.16)

The software is installed on the host PC using software installation files pro

-

vided with the device. At least one USB port (minimum USB 2.0) is required 

on the host PC to install the software as well as communicating with the 

device. While the software can run on Windows 7, it is recommended to run 

on Windows 10 or higher.

The software requires Microsoft Office (Office 365 or earlier) installed on the 

host PC for reporting capabilities.

The software is comprised of several modules that automatically interact with 

each other to share data; communicate with the hand-held device (via USB 

port); analyze experimental data to calculate oil, water (and brine), and solids 

fractions in Non-Aqueous Fluids (NAF); and for reporting and data analysis 

purposes.

The device can be operated while connected to the software or in stand-

alone mode. In connected mode, the software allows the user to input key 

information on the drilling fluid (inputs) and perform the measurement on the 

fluid. Once testing is complete, the software automatically collects measured 

data from the device, processes the data using sophisticated engineering 

analyses, displays results, generates Microsoft Excel-based reports, and 

archives test data and results for further analyses.

In stand-alone mode, the software communicates with the device to transmit 

drilling fluid input data. Once the device is updated, it can be disconnected 

from the host PC and perform measurements on the drilling fluid. Once test

-

ing is completed and the device is plugged back into the host PC, test data 

is automatically downloaded from the device and analyzed in the software. 

Analysis results and Excel-based reports can then be generated from the 

software.

Software

Architecture

Содержание MudChecker

Страница 1: ...5 21 ES MudChecker v1 5 ES Instruction Manual Updated 2 5 2024 Ver 2 OFI Testing Equipment Inc 11302 Steeplecrest Dr Houston Texas 77065 U S A Tele 832 320 7300 Fax 713 880 9886 www ofite com Copyrigh...

Страница 2: ...com 1 Introduction 2 Battery 3 Test Setup 4 Device Navigation 6 Testing 7 Standalone 7 With Software 9 Cleaning the Probe 10 Software 11 Introduction 11 Architecture 12 Installation 14 Layout 18 Resu...

Страница 3: ...g a second measurement step The MudChecker KS requires the user to manually input the salinity value before measuring the oil water and solids content The KS mode can also be selected on the ES models...

Страница 4: ...rt of a hub Checking the Battery The battery status is shown briefly when the device is powered on You can see the battery status at any time by powering the device off and then on Recharging the Batt...

Страница 5: ...f 17 characters Mud Density density of the whole drilling fluid in lb gal Weighted Mud specifies whether the mud contains barite If un weighted mud is being tested with no barite uncheck this selectio...

Страница 6: ...ty input mg Cl ions per liter of mud comes directly from the volume of Silver Nitrate used for titration mg CaCl2 per kg of brine or part per million weight percent CaCl2 in brine mg Cl ions per liter...

Страница 7: ...ecker device to the host computer 3 Start the MudChecker software Then click the Base Fluid Calibration button to display the Base Fluid Calibration screen 4 Insert the MudChecker probe into the base...

Страница 8: ...320 7300 Fax 713 880 9886 www ofite com 7 The MudCecker device has four navigation buttons Device Navigation Power Scroll Hold to Cancel or Power Off Navigate Down One Level in Menu Enter Increase or...

Страница 9: ...e All analyses are performed on the PC Multiple tests 100 max can be performed in this mode before results are downloaded to the host PC If multiple tests are performed the same set of input data will...

Страница 10: ...container into a blending cup Using a syringe measure out 20 mL of undiluted drilling mud and inject the mud into the DSX7 solution Blend the contents It is recommended Use a quality blender To avoid...

Страница 11: ...ots in the probe shield are submerged 2 Power on the device using the power button 3 Attach the probe to the MudChecker device Then insert the probe into your drilling fluid sample 4 Click the Run but...

Страница 12: ...nylon as this increases the risk of electrostatic discharge to the unit When cleaning the inner part of the probe hold the unit using the stainless steel collar at the top of the probe to reduce the...

Страница 13: ...held MudChecker drilling fluid analyzer unit Main Functions of the Software Communicate with the MudChecker to control the device and access data and measurements from the device Display test data and...

Страница 14: ...other to share data communicate with the hand held device via USB port analyze experimental data to calculate oil water and brine and solids fractions in Non Aqueous Fluids NAF and for reporting and...

Страница 15: ...ware as Windows normal feature of automatic USB detection will interfere with the communication between the software and the device which may cause the test to be prematurely terminated MudChecker dev...

Страница 16: ...USB thumb drive with the device To install the software 1 Insert the thumb drive into a USB port 2 Double click setup exe to start the installation 3 Click Next to select the installation location Ma...

Страница 17: ...time version 6 0 16 or higher is not available on the host PC then the software will automatically prompt the user to install it Please note that an Internet connection is required to download the re...

Страница 18: ...xe Please note that while the installation file from Micro soft may change based on the minimum requirement from Microsoft the system will automatically detect and install the minimum required frame w...

Страница 19: ...low 11 Run the windowsdesktop runtime 6 0 20 win x64 exe installation file to install the NET Framework Ensure that the software was installed cor rectly 12 Run the MudCheckerApp to verify that all ne...

Страница 20: ...areas of the main screen are grouped according to their functionality and are highlighted and described in the section below Action Bar The Action Bar allows the user to Run a New Measurement Test or...

Страница 21: ...automatically downloaded from the device and archived in the grid in the Test Archive group To download new tests simply connect the device to the host PC and then launch the software Since the device...

Страница 22: ...urrently connected to the host PC or can be viewed for all archived tests This can be performed by making the appropriate choice in the Tests header in the grid Records for a given device can be expan...

Страница 23: ...tric fraction of water in the sample similar to what would be measured on the retort Solids the volumetric percent of Solids in the drilling fluid sample simi lar to what would be measured on the reto...

Страница 24: ...t aqueous phase chloride concentration from calcium chloride expressed in milligrams per liter WPS CaCl2 mg lt aqueous phase calcium chloride concentration ex pressed in milligrams per liter WPS CaCl2...

Страница 25: ...065 USA Tel 832 320 7300 Fax 713 880 9886 www ofite com 24 Any archived test available in the host PC can be exported as an Excel based report The various groups in the report are similar to those des...

Страница 26: ...o the DSX7 solution be careful not to deposit the sample on the sides or on the blade assembly above the liquid line Switch on your blender To avoid splashing blend at the slowest speed and gradually...

Страница 27: ...any part of the equipment that is not expressly described in this guide Opening the equipment or tampering with its seals will invalid the warranty and is in breach of the terms and conditions of sal...

Страница 28: ...ed that the unit should not be exposed to direct sunlight for long periods of time If required to operate above this temperature please contact OFITE for advice Do not place the unit near a heat sourc...

Страница 29: ...y losses or damages that occur as a result of Improper installation or maintenance of the products Misuse Neglect Adjustment by non authorized sources Improper environment Excessive or inadequate heat...

Отзывы: