2

OFITE’s Model 20 Constant Speed Blender was designed to prepare well 

cements for testing according to the guidelines stated within API Specification 

10. Research has demonstrated that the properties of well cements are 

highly dependent upon mixing procedures. In addition, studies have indicated 

that when constant speed blenders/mixers are used, data obtained from 

thickening time tests has greater reproducibility and generally correlates 

better with data obtained from other laboratories. The Model 20 was designed 

to provide a means of consistently preparing cement slurries for testing 

purposes and can be utilized to mix cements according to the procedures 

stated by the API.

The proper amount of mix water is carefully weighed and poured into the 

mixing container of the blender. The rotational speed is set to 4,000 RPM 

and allowed to stabilize at this speed. The “TIMER” switch is pressed and 

the cement is immediately added to the mix water. The cement should be 

uniformly added to the water in less than 15 seconds. After 15 seconds the 

rotational speed is automatically increased to 12,000 RPM and the slurry is 

mixed an additional 35 seconds. A microprocessor is utilized to maintain the 

rotational speed within the recommendations established by the API and is 

independent of fluctuations in line voltage and the viscosity of the cement 

slurry.

The 120-60-F Constant Speed Blender is intended for testing Fracturing 

Fluids. The rotational speeds are set to 500 and 1,000 RPM respectively.

Intro

Description

Содержание 120-60

Страница 1: ...30 Volt 120 60 F For Fracturing Fluids 115 Volt 120 60 1 F For Fracturing Fluids 230 Volt Instruction Manual Updated 11 16 2015 Ver 5 0 OFI Testing Equipment Inc 11302 Steeplecrest Dr Houston Texas 77...

Страница 2: ...320 7300 Fax 713 880 9886 www ofite com 1 Intro 2 Description 2 Specifications 3 Components 3 Installation 7 Operation 8 Manual Mode 8 Variable Mode 9 Auto Mode 9 Timer 10 Speed Controller 10 PID Para...

Страница 3: ...be utilized to mix cements according to the procedures stated by the API The proper amount of mix water is carefully weighed and poured into the mixing container of the blender The rotational speed is...

Страница 4: ...5 Volt Only Qty 4 122 200 Blending Assembly Square Drive 1 qt Qty 12 122 202 Stainless Steel Container 1 qt 122 203 Container Lid 1 qt 122 204 Bottom Gasket Qty 6 120 61 1 Spare Parts Kit 230 Volt 122...

Страница 5: ...display shows the speed of the blade On models for cement testing 120 60 120 60 1 multiply the value displayed here by 10 to determine the actual RPM of the blade 2 Timer Display Seconds 3 Edit Setpo...

Страница 6: ...point value by 1 7 Enter Button Press this button to store the Setpoint value in memory 8 Timer Reset Press this button to reset the timer to zero 9 Keypad VAR This button accesses the PID Parameter C...

Страница 7: ...For testing Cement part numbers 120 60 and 120 60 1 Setpoint 1 is 4 000 RPM and Setpoint 2 is 12 000 RPM For testing Fracturing Fluids Setpoint 1 is 500 and Setpoint 2 is 1 000 RPM 15 Three Way Switch...

Страница 8: ...fely away from sinks and other possible hazards 2 Place the blending assembly on the base of the unit 3 Plug the power supply cord into the port underneath the cabinet housing labeled BLENDER 4 Plug t...

Страница 9: ...nd turn the Potentiometer 16 fully counter clockwise 1 Place the mix water into the mixing cup and place the lid on top of the container 2 The MAN AUTO Variable switch 13 should be in the MAN AUTO pos...

Страница 10: ...er position Place the MAN AUTO VARIABLE switch 13 to the MAN AUTO position Place the MANUAL AUTO switch 15 switch to the AUTO position Once the switch is placed into the AUTO position the blender shou...

Страница 11: ...e display 3 6 each increase a separate digit of the setpoint value The digits will scroll from 0 to 9 and then return to 0 3 When you reach the correct setpoint value press the enter button 7 to store...

Страница 12: ...ut the response was slow increase the value of Variable 9 by 4 Repeat the above procedure changing the value of VARIABLE 9 until there is minimal overshoot and the ramp is smooth Note that to fine tun...