CLEANING AND MAINTENANCE

Attention!

 During cleaning, do not wash the external parts of the appliance with direct sprays of water or with high 

pressure.
After every use, clean the appliance thoroughly. Daily cleaning after switching off the appliance ensures the perfect 
functioning and long life of the appliance.
Before starting to clean the appliance, disconnect the power supply. The parts in steel must be washed with hot 
water and neutral detergent, then rinsed thoroughly in order to eliminate all traces of detergent; after which, dried 
with a dry cloth. 
Do not use abrasive or corrosive detergents.

Important: 

As well as ordinary cleaning and maintenance, it is advisable to have the installation checked by an 

installer at least once a year.
It is therefore suggested to draw up an after-sales assistance contract.

Cleaning burnished brass surfaces

No synthetic protective varnishes have been used to obtain the special burnishing effect on the burnished brass 

details in order to avoid spoiling the beauty of the brass with an artificial patina.  The antique finish of the surface 

is the result of natural oxidation that has simply been accelerated.  All the natural antique finish brass surfaces can 

be cleaned with any kitchen degreasing detergent, accompanied by the use of an abrasive scouring pad (the 

green colored type used for washing dishes).  It is recommended that the metal be rubbed, uniformly applying light 

pressure, until the desired effect is achieved.  

The brass details should then be dried.  

Do not use polish as this is suitable for maintaining the gloss but not the antique finish and could result in an effect 

that is not compliant with our products.  Any spots that may appear over time on the burnished brass surfaces should 

be considered as a desirable and particular characteristic of our craft metal working processes. 

Cleaning chromium-plated brass surfaces

No synthetic varnishes have been used to obtain the special polish on the chromium-plated brass details in order to 

avoid spoiling the beauty of the chromium plating with an artificial patina.  All the chromium-plated surfaces should 

be cleaned, where necessary, with a soft, possibly micro-fiber cloth, combined with metal polishing products, if 

required.  Do not use abrasive pads.

Cleaning satin finish nickel-plated brass surfaces

No synthetic varnishes have been used to obtain the special nickel-plating on the satin finish nickel-plated brass 

details in order to avoid spoiling the beauty of the nickel-plated, satin finished solid brass with an artificial patina.  All 

the nickel-plated and satin finished brass surfaces should be cleaned, where necessary, with a soft, possibly micro-

fiber cloth, combined with a neutral detergent, if required.  Do not use abrasive pads.

Cleaning the varnished surfaces

All the varnished surfaces should be cleaned using a neutral detergent and, where necessary, a soft, possibly micro-

fiber cloth.  Do not use abrasive pads or any other chemical products.

Cleaning brushed steel surfaces

All the brushed steel surfaces should be cleaned using degreasing products or products specifically designed to be 

used on steel and, where necessary, extra-fine steel wool or extra-thin sandpaper.

15

Officine Gullo

WHAT TO DO IN THE EVENT OF A BREAKDOWN

In the event of breakdown, turn off the appliance, disconnect the power supply by using the device situated above 

the appliance and notify the after sales service.

PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT 

GOING TO BE USED FOR SOME TIME

Turn off the appliance, disconnect the power supply and clean the appliance as specified above.

MAINTENANCE (only for qualified personnel)

Any kind of maintenance must only be done by qualified personnel. Before carrying out maintenance,remove the 

plug or switch off the switch above the appliance.

Содержание CVS4E

Страница 1: ...INSTRUCTIONS FOR INSTALLATION AND USE CVS4E CVS6E CVCS4E CVCS6E ELECTRIC PASTA COOKER FOR RESIDENTIAL AND PROFESSIONAL USE...

Страница 2: ...le the appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and...

Страница 3: ...CTRICAL DATA TABLE 11 TRANSFORMATION 11 ELECTRIC CONNECTION 11 EQUIPOTENTIAL 12 USER MANUAL STARTING UP 12 INSTRUCTIONS FOR USE 12 TURNING ON 12 EMPTYING THE TUB CVCS E 13 EMPTYING THE TUB CVS4E CVS6E...

Страница 4: ...UAL FIG A 1 CVS4E 3 cm 4 cm 97 cm 62 cm 70 cm 90 cm 73 cm 67 cm E 70 cm 40 cm 20 cm 40 cm 40 cm E Su richiesta scarico posteriore Drain on the wall on request E LEGEND Electric connection Connessione...

Страница 5: ...Officine Gullo E Electrical connection F Water connection ISO 7 1 3 4 M S Water drainage ISO 7 1 1 M FIG A 2 CVCS4E E Electrical connection F Water connection ISO 7 1 3 4 M S Water drainage ISO 7 1 1...

Страница 6: ...70 cm 20 cm 60 cm 40 cm E 3 cm 4 cm 97 cm 62 cm 70 cm 90 cm 73 cm 67 cm E Su richiesta scarico posteriore Drain on the wall on request E LEGEND Electric connection Connessione Elettrica FIG A 3 CVS6E...

Страница 7: ...0 cm 20 cm 60 cm 40 cm E 3 cm 4 cm 97 cm 62 cm 70 cm 90 cm 73 cm 67 cm E Su richiesta scarico posteriore Drain on the wall on request E LEGEND Electric connection Connessione Elettrica E Electrical co...

Страница 8: ...witching Klemmenblock Bornier de commutation Switching terminal block Tablero de bornes de conmutaci n 5 Resistenze Widerst nde R sistances Elements Resistencias 6 Sonda di livello Pegelsonde Sonde de...

Страница 9: ...tation Switching terminal block Tablero de bornes de conmutaci n 4 Resistenze Widerst nde R sistances Elements Resistencias 5 Spia bianca Kontrolleuchte wei Lampe t moin blanche White pilot light Pilo...

Страница 10: ...ERISTICS The system must be connected to a drinking water supply with the following characteristics Failure to do so automatically invalidates the guarantee Total hardness 0 5 to 5 F to prevent the bu...

Страница 11: ...l contacts from the mains must be installed above it this device must have a contacts opening of at least 3 mm TECHNICAL ELECTRICAL DATA TABLE MODELS DIMENSIONS cm POWER SUPPLY Power max kW Absorbitio...

Страница 12: ...care Check the connection of the appliance and start it up following the instructions INSTRUCTIONS FOR USE Use the appliance only under surveillance Never start up the appliance without water With pas...

Страница 13: ...the safety device A upwards and move lever B to open the outlet tap Once emptied the tub close the outlet tap ANOMALIES If the probe does not detect the presence of water in the tank for more than 15...

Страница 14: ...uld then be dried Do not use polish as this is suitable for maintaining the gloss but not the antique finish and could result in an effect that is not compliant with our products Any spots that may ap...

Страница 15: ...the after sales service PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME Turn off the appliance disconnect the power supply and clean the appliance as specified above MAINTE...

Страница 16: ...Tel 39 055 656 0324 info officinegullo com Via Della Torricella 29 Antella Bagno a Ripoli 50012 Florence Italy OFFICINEGULLO COM en international V 2 3 9 18...

Отзывы: