Fit a gas filter upstream of the pressure regulator in order to optimise operating efficiency.
3. TECHNICAL FEATURES
The data plate is positioned on the left of the cabinet.
-
Appliance in category
-
Supply pressure: Butane/Propane (G30-G31) 28-30/37mbar
Natural gas (G20) 20mbar
TABLE 1
MODELLO
DIMENSIONI
mm
(L x P)
RACCORDO
GAS
PORTATA
GAS
kW
CONSUMO
GAS
Kg/h
CONSUMO
GAS
m
3
/h
TIPO
UNICO SERIES
UNICO SERIES
400x730
800x730
1/2” Gc ISOR7
7
14
0,55
1,10
0,74
1,48
A1
A1
6 UNICO SERIES
6 UNICO SERIES
350x630
700x630
1/2” Gc ISOR7
6
12
0,47
0,95
0,63
1,27
A1
A1
TABLE 2
FOR UNICO SERIES APPLIANCES 400x730x900H
NOMINAL CAPACITY kW 7 REDUCED CAPACITY kW 3
Main burner
injectors
Ø 1/100 mm
Pilot light injectors
No.
By-pass
Ø 1/100 mm
Primary air pos.
main burner
(size in mm)
Liquid gas
(G30 28...30mbar)
95*
24*
90
-
Natural gas
(G20 20mbar)
140R*
29.2*
Adjustable
-
For appliances UNICO series (800x730x900H) with nominal capacity 7 + 7 = 14 kW and reduced capacity
3 + 3 = 6 kW the injectors are double.
TABLE 3
FOR APPLIANCES “6 UNICO” SERIES 350x630x285H
NOMINAL CAPACITY kW 6 REDUCED CAPACITY kW 1,7
Main burner
injectors
Ø 1/100 mm
By-pass
Ø 1/100 mm
Primary air pos.
main burner
(size in mm)
Liquid gas
(G30 28...30mbar)
125
70
4.0
Natural gas
(G20 20mbar)
190
Adjustable
1.0
For appliances
“6 UNICO” series (700x630x285) with nominal capacity 6 + 6 = 12 kW and reduced capacity
1.7 + 1.7 = 3.4 kW the injectors are double.
TABLE 4
700 UNICO SERIES
DIMENSIONS
PLATE DIMENSIONS
PLATE COMPOSITION
kW
U70FTG40L
400x730x900
360x570
Smooth
7
U70FTG80L
800x730x900
755x570
Smooth
14
U70FTG80LR
800x730x900
755x570
Half smooth
– half scored
14
6 UNICO SERIES
DIMENSIONS
PLATE DIMENSIONS
PLATE COMPOSITION
kW
6UFTG35L
350x630x285
330x510
Smooth
6
6UFTG70L
700x630x285
680x510
Smooth
12
6UFTG70LR
700x630x285
680x510
Half smooth
– half scored
12
4. OPERATION WITH SUPPLY GAS IDENTICAL TO THAT AVAILABLE
Check whether the indications on the data plate correspond to the gas distributed.
Also check correspondence to the indications below.
4.1 Checking the supply pressure (Fig. 3)
The supply pressure can be measured by means of a pressure gauge with a
U-shaped pipe, or of the electronic type with a minimum grading of 0.1 mbar.
-
Unscrew the screw “A” from the pressure tap “B”.
-
Position the pressure gauge.
-
Switch on the appliance and check that the pressure is the one intended:
otherwise check on the cause.
-
At the end of the operations, reassemble the appliance and check the
connection.
B
A
Fig. 3