10
Open stop valve and start unit by means of the ON/OFF switch (2). The
pipe cleaning nozzle is automatically drawn in due to the recoil effect.
As soon as the nozzle hits the clogging, carefully pull back the hose and
let it move in again, in order to flush out the clogging. Work in sections
and avoid excessive dirt removal, in order to avoid that the pipe is
clogged again.
During removal of the pipe cleaning hose stop machine as soon as
the marking is reached (approx. 50 cm before the end is reached),
as otherwise the hose would flap around so causing severe
injuries. If no marking is detected, apply one by tape or paint.
After Work
•
Switch off machine by means of the ON/OFF switch (2).
•
Depressurize spray pistol by shortly opening
and closing.
•
Lock
spray
pistol.
•
Disconnect machine from water and power source.
•
Thoroughly clean high pressure hose. In case of
damage
(cuts, abrasions, kinks, etc.) replace high
pressure hose for safety reasons.
•
Only original OERTZEN high pressure hoses to be used.
Otherwise Declaration of Conformity and warranty will expire.
•
Reel up high pressure hose properly without any loops.
•
Store machine and accessories in a dry, frost-protected area.
•
Drain pump completely in case of extended shut-down periods.
Particularly note:
In case of malfuctions, eliminate cause according to chapter „Trouble
Shooting“, call qualified service.
In case frost is likely, frost protection to be carried out (see chapter
„Maintenance and Care“), otherwise severe damage will be the result.