UNPACKING YOUR CLEANER
Unpack your cleaner and ensure that you have a complete set of ac ces so ries as listed below:
Qty Part No. Description
1
K14.01.01 32mm x 2.5m Hose Assembly
1
K14.02.02 32mm Stainless Steel Bent Hose End with Suction Adjuster
2
K14.02.03 32mm Stainless Steel Wands
1 K14.03.01 32mm Combination Tool
1 K14.04.01 32mm Stair Tool
1 K14.04.02 32mm Crevice Tool
1
K14.04.06 32x70mm Dusting Brush
1
K14.04.09 32mm Double Taper Tube
5
K18.01.01 K1 Disposable Microfi bre Bag (KV10 & 15H)
5
K18.01.02 K4 Disposable Microfi bre Bag (KV18H)
1
K24.01.01 11" High Effi ciency Filter Assembly (KV10H)
1
K24.02.01 12" High Effi ciency Filter Assembly (KV15 & 18H)
Note: The KV18/1H model is also available with a 38mm toolkit in place of the 32mm toolkit.
GENERAL ASSEMBLY
1. Hose
Fit the threaded end of the hose onto the hose connection on the cleaner and turn in a clockwise direction to
lock into place.
2. Bent Hose End & Wands
To connect the wands and tools simply push the appropriate items together until secure. To disconnect fi rmly
hold one item and gently twist and pull the other to separate.
RISK ASSESSMENT Type H
If this vacuum cleaner is used for collecting dust and debris which may be hazardous to health if inhaled,
ingested or in contact with the skin then a risk assessment must be carried out by a competent person to verify
the suitability of the application.
The risk assessment will be the responsibility of the customer/end user and should take into account but not
limited to the characteristics of the material being collected such as:
1. The occupational exposure limit of the dust and debris being collected.
2. The particle size of the dust and debris being collected.
3. The method of disposal.
OPERATING INSTRUCTIONS
WARNING Before use operators must be provided with information, instruction and training for the use of this
vacuum cleaner and the substances for which it is to be used, including the safe method of removal and disposal
of the material collected.
1. Connection to the Electricity Supply
Insert the mains plug into a suitable socket outlet and switch on. When you have fi nished cleaning, switch off
the supply at the outlet socket and unplug. When coiling the mains cable make sure that any twists or knots in
the cable come out at the plug end. DO NOT coil cable from the plug end as all twists and knots remain in the
cable and considerably shorten its life.
YELLOW FLASHING WARNING LIGHT
This model is fi tted with a yellow fl ashing LED warning light. When this light is fl ashing the airspeed in the
hose has dropped below 20 metres per second. This would indicate that there is an impediment to the airfl ow.
1.
Remove hose. If LED stops fl ashing, the hose is blocked. Unblock the hose and try again.
2. If
LED
fl ashes with no hose connected, there is a restriction in the air fi ltration system. Use the following
sequence to check, replace or clean the following:
a) Disposable
Microfi bre bag
b) High
Effi ciency fi lter assembly
c)
HEPA Cartridge fi lter
<20 m/s
1
a
b
c
2
3
2
1
1
5
2
3
4
3