2. Cleaner Controls
The following controls are provided:
a)
The on/off switch is situated at the rear of the motor head. To switch the appliance on fi rmly press the part
of the switch marked “1”. To switch off press the part of the switch marked “0”.
b) The suction regulator situated on the bent hose end is used to vary the amount of suction power available.
In the closed position maximum suction power is available and in the open position less suction power is
available.
3. Carrying and Storing
The assembled cleaner should only be moved by the carrying handle on top of the motor head
(not applicable
to the KV18H on a caddy)
. Do not attempt to lift or drag the machine by the mains cable. The cleaner must be
stored indoors and in a dry environment.
All
Type H vacuum cleaners are supplied with screw-on blanking caps. These are designed to seal the
inlet and exhaust ports to prevent the escape or ingress of hazardous dust during transport or storage. Whenever
this vacuum cleaner is not in use these blanking caps should be used. They must be removed before use.
FILTRATION SYSTEM
This is a Type H Vacuum Cleaner. It is fi tted with 3 stages of fi ltration on the negative pressure side of the motor
(that is before the motor, so that the motor always receives clean fi ltered air).
1st Stage:
Disposable Microfi bre Bag
2nd Stage: High Effi ciency Filter Assembly
3rd Stage: Type H HEPA (High Effi ciency Particulate Air) Cartridge Filter
Also known as the Absolute or Essential Filter
KV10/1H HEPA Filter Part No. K27.03.02
KV15 & 18/1H HEPA Filter Part No. K27.03.03
Access to the Microfi bre Bag and Filtration System
a)
To remove the motor head and HEPA cartridge unit, unclip the LOWER set of clips. Ensure that the clips
are hinged clear of the rim of the HEPA unit. Lift the motor head and HEPA unit clear of the canister.
b) To
refi t the motor head and HEPA unit align the head so that the switch and cable entry lie directly opposite
the hose entry on the canister. Locate the clips over the rim of the HEPA unit and fi rmly press down both
clips until they have locked into position.
Note: The upper set of clips between the HEPA unit and motor head have a lock-down screw to prevent the
separation of the motor head from the HEPA unit.
Only authorised and trained personnel should separate the motor head from the HEPA unit.
WARNING
This vacuum cleaner may contain dust hazardous to health. Emptying and maintenance operations including
removal and renewal of dust collection bag shall only be carried out by authorised personnel wearing suitable
approved personal protection.
WARNING
Do not use this vacuum cleaner unless the full fi ltration system is fi tted – Type H cartridge, High Effi ciency fi lter
assembly and Microfi bre bag. Failure to fi t the complete system may cause premature clogging of the Type H
cartridge and may also endanger health.
WARNING
Do not use this vacuum cleaner for the collection of explosive dusts.
Do not use this vacuum cleaner in a corrosive or fl ammable environment.
IMPORTANT
This vacuum cleaner is designed to collect hazardous dusts. Therefore any dust found within the machine or on
its fi lters may be dangerous to your health. Always take precautions.
DUST/DEBRIS DISPOSAL
This
vacuum cleaner
contains dust hazardous to health. Emptying and maintenance operations, including removal
and renewal of dust collection bag, must only be carried out by authorised personnel wearing suitable personal
protection. Do not operate without the full fi ltration system fi tted.
Disconnect the hose, fi t the blanking cap on the hose entry, unlatch the clips and remove the motor head/HEPA
unit. Take care not to drop the motor head/HEPA unit. Remove the fi lter assembly and carefully release the
disposable bag from the bag tube and lift out of the canister. Seal the disposable bag inlet using the integral cap
on the bag collar. The disposable bag should be immediately placed in a suitably labelled impervious plastic
bag and this bag sealed and disposed of in accordance with the current regulations. Fit new disposable bag over
the bag tube inside the canister.
This vacuum cleaner is supplied with 5 spare Microfi bre bags and a spare fi lter assembly. This (clean) spare fi lter
should be used and the motor head/HEPA unit refi tted.
The contaminated fi lter should now be cleaned by using this
vacuum cleaner
and stored in a labelled plastic bag
ready for future use.
DECONTAMINATION
Decontamination operations should only be carried out by competent authorised personnel equipped with
suitable personal protection.
Before removing the accessories/vacuum cleaner from the contaminated area:
• Accessories should be cleaned externally with a Type H vacuum cleaner.
• They should then be cleaned with an adhesive wipe, sealed at each end and sealed in a clear impervious bag.
The bag should carry an appropriate warning label.
• The external surfaces of the bag should then be cleaned with an adhesive wipe.
• The vacuum cleaner should be cleaned externally with itself. The disposable bag and its contents should be
removed and disposed of in accordance with the method described in the section titled Dust/Debris Disposal.
• The vacuum cleaner should then be cleaned externally with an adhesive wipe.
• The vacuum cleaner should be sealed in a clear impervious bag. The bag should carry an appropriate warning
label.
• The external surfaces of the bag should then be cleaned with an adhesive wipe.
MAINTENANCE
Maintenance must be carried out in a suitable controlled area with local fi ltered exhaust ventilation and facilities
for cleaning the area after servicing.
During maintenance always disconnect from the electrical supply.
Maintenance and cleaning must only be carried out by competent authorised personnel equipped with suitable
personal protection. All parts must be regarded as contaminated. Another Type H vacuum cleaner should be
used to clean each component.
Items that cannot be satisfactorily cleaned are to be disposed of in impervious plastic bags in accordance with
current regulations. All surfaces should be cleaned as they become exposed.
THERMAL CUTOUT SWITCH
This vacuum cleaner is fi tted with a thermal switch which automatically stops the motor if it overheats. This
may be caused by a blocked hose or wands, a full Microfi bre bag, or a blocked fi lter. If your vacuum cleaner cuts
out check for the above. The thermal switch will automatically reset itself when the motor temperature drops.