ENG
36
Service settings manual
FUNCTION PARAMETERS
Table with description of parameters :
Parameter
Function
Description
Setting range
Default
value
F1.1
Heat metering
With this setting we activate the system which measures
acquired solar energy.
0 - OFF
1 - ON
0
F1.2
Medium
Select transfer medium in the solar system.
0 - water
1 - Propylenglycol
2 - Ethylenglycol
3 - Tyfocor
4 - Tyfocor LS,
G-LS
0
F1.3
Antifreeze concentration
Set the antifreeze concentration.
By Tyfocor LS and G-LS this setting has no effect.
10 ÷ 100 %
40
F1.4
Hot sensor
Select the sensor which is in collectors.
1 - T1 (T3)
2 - T2
3 - T3
4 - T4
5 - T5
1
F1.5
Cold sensor
Select the sensor Tc which is on the return pipe into
collectors.
1 - T1
2 - T2
3 - T3
4 - T4
5 - T5
5
F1.6
Flow meter
With settings you define whether there is a built-in flow
meter.
0 - NO
1 - YES
0
F1.7
Impulse rate of flow
meter
You insert characteristic data of flow meter i.e. amount of
volume per impulse.
0,1 ÷ 100 l/imp
1
F1.8
Flow in first collector
field
If you do not use the flow meter, read out and set flow
from the mechanic flow meter in first collector field when
the pump is running at 100 %.
1 ÷ 100 l/min
6
F1.9
Flow in second collector
field
If you do not use the flow meter, read out and set flow
from the mechanic flow meter in second collector field
when the pump is running at 100 %.
1 ÷ 100 l/min
6
F1.10
Flow in first and second
collector field
If you do not use the flow meter, read out and set flow
from the mechanic flow meter for both collector fields
when both pumps are running at 100 %.
This setting is used only by schems where both collector
fields can operate simultaneously.
2 ÷ 100 l/min
12
The procedure for setting function parameters is the same as for service pa-
rameters (see page 31).
Function parameters are arranged in groups F1 and F2. Group F1 contains parameters to
set the solar heat metering. Group F2 contains parameters for free programming of relay
output R1 operation.